A fax-back oxygenator-perfusionist clinical performance data collection and statistical analysis method.

نویسندگان

  • J B Riley
  • R G Berryessa
  • G A Justison
  • K M Nolan
  • H R Hoerr
چکیده

A method to collect clinical oxygenator performance data daily is described. At the end of a bypass procedure, the perfusionist fills in a fax-back form designed to automatically input patient-oxygenator performance data into a computer spreadsheet. Multiple blood gases, FiO2, gas and blood flow data, venous oxygenator blood inlet conditions (hemoglobin, O2 saturation, hematocrit and temperature), time on bypass and device manufacturer information are collected at the end of each cardiopulmonary bypass procedure at multiple institutions. A large sample database is created that allows multi-parametric analyses in regard to clinical practice, device performance, manufacturing consistency and patient requirements. The database and analyses facilitate institutional, manufacturer, and clinician benchmarking. Monthly reports to the clinicians give valuable feedback to improve oxygenator use and patient blood gas control. Reports to the device manufacturer provide information used to evaluate the clinical consequences of small changes in the manufacturing process.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting oxygenator clinical performance from laboratory in-vitro testing.

Knowledge and predictability of oxygenator performance is vital to safe and effective conduct of cardiopulmonary bypass. The determination of oxygenator performance in the laboratory, however, is carried out under a strict set of conditions established by the Association for the Advancement of Medical Instrumentation (AAMI). This performance data is of limited value in the clinical setting wher...

متن کامل

Alpha-stat capnography for the Sorin Monolyth oxygenator.

Monitoring the carbon dioxide exhaust of an oxygenator is an inexpensive method to accurately predict and control the arterial carbon dioxide tension during cardiopulmonary bypass (CPB). The partial pressure of carbon dioxide in the exhaust ventilating gas (p exCO 2) was continuously monitored from the capnograph port of the Sorin Monolyth oxygenator during CPB. At the time of routine arteria...

متن کامل

An in vitro protocol for evaluation and comparison of membrane oxygenators.

With the trend in open heart surgery toward normothermic bypass and warm blood cardioplegia, greater demand is being placed on the perfusionist to select an oxygenator that will perform safely and efficiently under a variety of conditions. While manufacturers report performance parameters for their products, the data is often not comparable due to widely differing conditions. Recent in vitro ...

متن کامل

A Novel Method to Detect an Oxygenator Defect Prior to Cardiopulmonary Bypass Initiation.

Cardiopulmonary bypass (CPB) is a common practice in our era. The medical technology used for cardiac surgery goes through rigorous testing to ensure its safety. Unfortunately, it is not fail proof. Oxygenator failures are a rare occurrence but may lead to catastrophic events. We present a case where the preparation for initiating CPB was complicated by an oxygenator defect. After thorough exam...

متن کامل

Assessment of the efficiency of banks accepted in Tehran Stock Exchange using the data envelopment analysis technique

The research provides a systematic method for assessing the financial performance of the banks. The analysis is based on a set of benchmarks related to the financial performance of the banks. In this regard, this research has explored a model for evaluating accepted banks in Tehran Stock Exchange using the data envelopment analysis method. The purpose of this research is to apply the research m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 1998