Intraocular pressure and ocular rigidity after LASIK.

نویسندگان

  • Sebastião Cronemberger
  • Cláudia Savassi Guimarães
  • Nassim Calixto
  • José Márcio Fonseca Calixto
چکیده

PURPOSE To assess the intraocular pressure (IOP) and ocular rigidity (E) at 1, 3, 6 and 24 postoperative months in eyes that underwent LASIK. METHODS The IOP measured by Goldmann applanation tonometer (GAT) and by the 5.5 and 10 gm. weights of a standardized Schioetz tonometer (ST) and the E measured by differential tonometry (the 5.5 and 10 gm. of ST) were assessed before and after LASIK (at 1, 3, 6 and 24 month) in 23 eyes. The volume of the corneal indentation (Vc) and IOP with ST resting on the eye (tonometric pressure - Pt) were also evaluated. RESULTS The average IOP (GAT) at 6 and 24 months after LASIK was lower than at 1 and 3 months and before LASIK. A statistically significant difference of E was found at 1, 3, 6 and 24 months. The reduction of the central corneal thickness (CCT) by LASIK was the cause of increasing values of Vc and decreased values of Pt. In turn, the changes in Vc and Pt were responsible for the lower IOP measurements by GAT and E changes. CONCLUSIONS LASIK reduces IOP readings by GAT but not the ones by ST (differential tonometry). LASIK also diminishes E. IOP (GAT) values are lower at 6 and 24 months. IOP evaluation by ST is more accurate than that by GAT. At 6 months, Vc, Pt and E parameters are stabilized (no changes relatively to 24 months measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Examination of ocular biomechanics with a new Scheimpflug technology after corneal refractive surgery.

PURPOSE To analyze the early results of a new device measuring ocular biomechanics after corneal refractive surgery. PATIENTS AND METHODS Thirty nine refractive surgery patients were enrolled in the study (age: 32.6±9.9 years). Laser in situ keratomileusis (LASIK) was performed on 52 eyes of 26 patients and photorefractive keratectomy (PRK) was done on 26 eyes of 13 patients. Ten device-speci...

متن کامل

Refinement of Intraocular Pressure Measurements made by Ocular Response Analyzer following Laser in Situ Keratomileusis using M2 90 Moria Microkeratome for Egyptian Myopic and Astigmatic Patients

INTRODUCTION The Goldmann applanation tonometer readings were noted to be markedly reduced after Lasik surgery using a thin flap technique which is widely used nowadays, to correct a wide range of myopia and astigmatism. The Ocular Response Analyzer (ORA) is considered one of the important tools for refinement of Intraocular Pressure (IOP) measurements. The aim of this study is to evaluate and ...

متن کامل

Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery

BACKGROUND The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer corneal compensated IOP (ORA IOPcc) and Pentacam corrected IOP. METHODS A prospective comparative clinica...

متن کامل

Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope

Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materia...

متن کامل

LASIK interface complications: what is the appropriate term for PISK?

To the Editor: We read with great interest the article “LASIK Interface Complications: Etiology, Management, and Outcomes” by Randleman and Shah.1 We agree completely with the authors when they stated: “Clarifying the nomenclature used for each entity is critical to enhancing future communication.” It is especially important in the most rare conditions, including the one they called “pressurein...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 72 4  شماره 

صفحات  -

تاریخ انتشار 2009