Clinical experience with the Tracey technology wavefront device.
نویسندگان
چکیده
PURPOSE In refractive surgery, measuring the total ocular profile of refraction gives more vital information than measuring the cornea alone. We report the first clinical experiments with spatially resolved refractometry using ray tracking principles. Tracey technology was developed in Ukraine by the Institute of Biomedical Engineering in cooperation with the Vardinoyannion Eye Institute of Crete. METHODS The Tracey-1 device was evaluated in comparison with conventional videokeratoscopes. Seven pseudophakic eyes of 7 patients and two phakic eyes were measured thirty (30) consecutive times (consecutively) each to test reproducibility. Measurements were provided in zones 0 to 5 (6) mm. For each zone, parameters of astigmatism were calculated and mean value and standard deviation were derived. RESULTS Standard deviation on the order of 0.14 D was derived. CONCLUSION The Tracey Technology wavefront device provides information on the refraction distribution at the first principal plane of the ocular optical system. For the instrument to provide measurements that are directly applicable to clinical practice, the data should be transposed to the corneal plane. The Tracey device can be utilized for the measurement of accommodative amplitude and range. Further development of the instrument is requred to increase its accuracy.
منابع مشابه
Application and Development of Wavefront Sensor Technology
Wavefront sensing technology can directly test the phase distribution of wavefront distortion and has the advantages of simple operation, real-time and large dynamic range. It is widely used in adaptive optics, laser beam quality diagnosis, laser atmospheric communication, optical element and optics system detection, quantitative phase microscope, human eye aberration measurement and other fiel...
متن کاملUse of a Two-Channel Moiré Wavefront Sensor for Measuring Topological Charge Sign of the Vortex Beam and Investigation of Its Change Due to an Odd Number of Reflections
One of the solutions of the Helmholtz equation is the vortex beams. In the recent decades, production and applications of these types of beams have found serious attentions. Determination of the vortex beam topological charge and its sign are very important issues. Odd number of reflections of the vortex beam changes its vorticity. In this paper, we have used a q-plate to generate a vortex beam...
متن کاملPyramidal Wavefront Sensor Demonstrator at INO
Wavefront sensing is one of the key elements of an Adaptive Optics System. Although Shack-Hartmann WFS are the most commonly used whether for astronomical or biomedical applications, the high-sensitivity and large dynamic-range of the Pyramid-WFS (P-WFS) technology is promising and needs to be further investigated for proper justification in future Extremely Large Telescopes (ELT) applications....
متن کاملWavefront Aberrations
Lower order aberrations are another way to describe refractive errors: myopia, hyperopia and astigmatism, correctible with glasses, contact lenses or refractive surgery. Lower order aberrations is a term used in wavefront technology to describe second-order Zernike polynomials. Second-order Zernike terms represent the conventional aberrations defocus (myopia, hyperopia and astigmatism). Lower o...
متن کاملWavefront ablation profiles in refractive surgery: description, results, and limitations.
PURPOSE To provide an overview of the clinical results of different ablation profiles based on wavefront technology and discuss their characteristics and limitations. METHODS Literature review of studies reporting results of ablation profiles based on wavefront technology in virgin healthy eyes. RESULTS Over the past 10 years, a large number of studies comparing different treatment algorith...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of refractive surgery
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2000