The High Resolution Powder Diffraction Beam Line at ESRF

نویسنده

  • A. N. Fitch
چکیده

The optical design and performance of the high-resolution powder diffraction beam line BM16 at ESRF are discussed and illustrated. Some recent studies carried out on BM16 are described, including crystal structure solution and refinement, anomalous scattering, in situ measurements, residual strain in engineering components, investigation of microstructure, and grazing-incidence diffraction from surface layers. The beam line is built on a bending magnet, and operates in the energy range from 5 keV to 40 keV. After the move to an undulator source in 2002, it will benefit from an extented energy range up to 60 keV and increased flux and resolution. It is anticipated that enhancements to the data quality will be achieved, leading to the solution of larger crystal structures, and improvements in the accuracy of refined structures. The systematic exploitation of anisotropic thermal expansion will help reduce the effects of peak overlap in the analysis of powder diffraction data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Certification of NIST Standard Reference Materials for Powder Diffraction

In the 12 years since the last Accuracy in Powder Diffraction meeting, there have been significant advances. Just an example: a search of the Protein Data Bank for “powder” shows just 2 hits for before 2000, 19 for 2000‐2005, 27 for 2005‐2010 and 31 for 2010‐present. The current Cambridge Crystallographic Data Base (CCDC) shows 2354 molecular crystal structures determined via powder diffraction...

متن کامل

Beamline P02.1 at PETRA III for high-resolution and high-energy powder diffraction

Powder X-ray diffraction techniques largely benefit from the superior beam quality provided by high-brilliance synchrotron light sources in terms of photon flux and angular resolution. The High Resolution Powder Diffraction Beamline P02.1 at the storage ring PETRA III (DESY, Hamburg, Germany) combines these strengths with the power of high-energy X-rays for materials research. The beamline is o...

متن کامل

The charge density of urea from synchrotron diffraction data.

The charge density of urea is studied using very high precision single-crystal synchrotron-radiation diffraction data collected at the Swiss-Norwegian Beam Lines at ESRF. An unprecedented resolution of 1.44 A(-1) in sin theta;/lambda is obtained at 123 K. The optimization of the experiment for charge-density studies is discussed. The high precision of the data allowed the refinement of a multip...

متن کامل

Multiple-detector System for Powder Diffraction Using Synchrotron Radiation

A multiple-detector system for powder diffraction using synchrotron radiation was built and has been operated at the Photon Factory in Tsukuba since May, 1995. The optics design is based on a flat-specimen-reflection geometry using parallel-beam, and the intensity data are collected by using asymmetric 2@stepscanning at a fixed incident angle. The multiple-detector system makes it possible to c...

متن کامل

A portable powder-liquid high corrosion-resistant reaction cell for in situ X-ray diffraction and absorption studies of heterogeneous powder-liquid reactions and phase transformations

A portable powder-liquid high corrosion-resistant reaction cell has been designed to follow in situ reactions by X-ray powder diffraction and X-ray absorption spectroscopy techniques in transmission mode. The cell has been conceived to be mounted on the experimental stations for diffraction and absorption of the Spanish CRG SpLine-BM25 beamline at the ESRF. In the case of the diffraction techni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 109  شماره 

صفحات  -

تاریخ انتشار 2004