Fiber-optic immunosensor for measurement of myoglobin.

نویسندگان

  • C M Hanbury
  • W G Miller
  • R B Harris
چکیده

A self-contained fiber-optic immunosensor was developed to measure the 16,500-Da protein myoglobin. The sensing element was constructed by entrapment of Cascade Blue-labeled antibody within polyacrylamide gel at the distal face of an optical fiber 300 microns in core diameter. The polyacrylamide gel composition was optimized to allow diffusion of myoglobin but to exclude hemoglobin and higher-molecular-mass proteins from the sensing area. The analytical signal was derived from fluorescence energy transfer between Cascade Blue and the heme group of myoglobin. Fluorescence quenching occurred when myoglobin bound to labeled antibody. The total amount of fluorescence quench was dependent on the antibody labeling conditions and the amount of antibody incorporated in the sensor gel matrix. Myoglobin concentrations > 5 nmol/L (83 micrograms/L) were measurable with response times of 15 to 130 min limited by diffusion into the sensing element. This report demonstrates the technical feasibility for a self-contained immunosensor to measure a protein analyte.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Portable Evanescent Wave Optic Fiber Immunosensor for Sensitive and Rapid Detection of 2,4-D in Water Samples

A portable evanescent wave optic fiber immunosensor was developed for detection of 2,4-dichlorophenoxyacetic acid(2,4-D) using a indirect competitive immunoassay. In this paper, hapten conjugates 2,4-D-OVA were immobilized with covalent binding methods. After pre-reacting, 2,4-D-antibody-Cy5.5 in sample specifically recognized the 2,4-D antigens binding sites on surface of the optical fiber pro...

متن کامل

Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results

Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature b...

متن کامل

Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7

A rapid and reproducible fiber-optic immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) was described. The biosensor consisted of a flow cell, an optical fiber with a thin Ni layer, and a PC linked fluorometer. First, the samples with E. coli O157:H7 were incubated with magnetic beads coated with anti-E. coli O157:H7 antibodies and anti-E. coli O157:H7 antibodies labeled cyanine 5 (Cy5...

متن کامل

Fiber - Optic Sensing of Linear Thermal Expansion (RESEARCH NOTES)

The use of a LED fiber-optic sensor to measure displacement and linear thermal expansion is described. It has a sensitivity of about 0.6 mV/mm, a resolution of 1.25 mm, and a dynamic rang of 400 mm for displacement measurements. For thermal expansion, it shows a sensitivity of about 3.5 mV/C, and the experimental linear expansion values are in agreement with those calculated. The reported senso...

متن کامل

A fiber optic sensor for measuring glucose in aqueous solutions

In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 43 11  شماره 

صفحات  -

تاریخ انتشار 1997