Percutaneous fiducial marker placement under CT fluoroscopic guidance for stereotactic body radiotherapy of the lung: an initial experience
نویسندگان
چکیده
The aim of this study is to describe our initial experience with the VISICOIL, which is the first percutaneous fiducial marker approved for stereotactic body radiotherapy in Japan, and to evaluate its technical and clinical efficacy, and safety. Eight patients underwent this procedure under CT fluoroscopic guidance. One patient had two tumors, so the total number of procedures was nine. We evaluated the technical and clinical success rates of the procedure and the frequencies of complications. Technical success was defined as when the fiducial marker could be placed at the target site, and clinical success was defined as when stereotactic body radiotherapy could be performed without the marker dropping out of position. The technical success rate was 78% (7/9). In one of the two failed cases, we aimed to place the marker inside the tumor, but misplaced it beside the tumor. In the other failed case, we successfully placed the marker beside the tumor as planned; however, the marker migrated to near the pleura after the patient stopped holding their breath. None of the markers dropped out of place, so the clinical success rate was 100% (9/9). The complication rates were as follows: pneumothorax: 56% (5/9), pneumothorax necessitating chest tube placement: 44% (4/9), focal intrapulmonary hemorrhaging: 67% (6/9), hemoptysis: 11% (1/9), mild hemothorax 11% (1/9), air embolism 0% (0/9), and death 0% (0/9). In conclusion, this new percutaneous fiducial marker appears to be useful for stereotactic body radiotherapy due to its good stability.
منابع مشابه
Percutaneous fiducial marker placement prior to stereotactic body radiotherapy for malignant liver tumors: an initial experience
The aim of this study was to describe our initial experience with a gold flexible linear fiducial marker and to evaluate the safety and technical and clinical efficacy of stereotactic body radiotherapy using this marker for malignant liver tumors. Between July 2012 and February 2015, 18 patients underwent percutaneous fiducial marker placement before stereotactic body radiotherapy for malignant...
متن کاملCardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: a case report
INTRODUCTION In liver stereotactic body radiotherapy, reduction of normal tissue irradiation requires daily image guidance. This is typically accomplished by imaging a surrogate to the tumor. The surrogate is often an implanted metal fiducial marker. There are few reports addressing the specific risks of hepatic fiducial marker implantation. These risks are assumed to be similar to percutaneous...
متن کامل[Treatment of lung lesions by stereotactic body radiation therapy after computed tomography guided placement of a Visicoil(®) marker: initial experience].
OBJECTIVE To describe the technique of stereotactic body radiation therapy (SBRT) of lung lesions after the computed tomography (CT) guided placement of an internal fiducial marker and to assess the results, complications and secondary effects of these procedures. MATERIAL AND METHOD A series of 39 lesions (8 primary and 31 metastases) in 25 patients treated using this procedure were analysed...
متن کاملIntravascular Placement of Metallic Coils as Lung Tumor Markers for CyberKnife Stereotactic Radiation Therapy
OBJECTIVE To present our experience with placing endovascular coils in pulmonary arteries used as a fiducial marker for CyberKnife therapy and to describe the technical details and complications of the procedure. MATERIALS AND METHODS Between June 2005 and September 2013, 163 patients with primary or secondary lung malignancies, referred for fiducial placement for stereotactic radiosurgery, w...
متن کاملC-arm fluoroscopic cone beam CT for guidance of minimally invasive spine interventions.
BACKGROUND Isocentric C-arm fluoroscopic cone beam CT (CBCT) is a new technique for near real time 3-D volume imaging guidance of percutaneous interventional procedures. In combination with digital flat panel detectors, CBCT has high spatial resolution with isotropic voxel size, allowing for high resolution image reconstruction in any plane, including 3D rotational reconstructions. CBCT combine...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 54 شماره
صفحات -
تاریخ انتشار 2013