Dark-room Prone-position Test for Intermittent Angle Closure
نویسندگان
چکیده
PURPOSE To determine the efficacy and safety of the dark-room prone-position test (DRPT) for intermittent angle closure (IAC) and to investigate the correlation between A-scan ultrasound biometric measurements and the results of DRPT. METHODS Medical records were reviewed of 37 eyes in 24 patients who were diagnosed with IAC and received DRPT. The increase of intraocular pressure (IOP) induced by DRPT and the results from A-scan ultrasound biometric measurements were obtained. An increase in IOP of at least 8 mmHg from baseline was considered a positive result for DRPT. Associations between the increase of IOP induced by DRPT and the parameters of A-scan biometry were tested by linear regression analysis. RESULTS The DRPT results were positive in 28 eyes of 19 patients. After DRPT, the IOP returned to near-baseline levels within 2 hours in all patients; some patients were treated with anti-glaucoma eye drops. Lens thickness was significantly correlated with the amount of IOP elevation induced by DRPT (r=0.338, p=0.041). CONCLUSIONS DRPT is a safe and effective test in patients with IAC. DRPT can be used effectively to make a concrete diagnosis of IAC. Lens thickness appears to be associated with a positive response to DRPT.
منابع مشابه
Evaluation of laser iridectomy in angle-closure glaucoma: provocative tests.
An argon laser iridectomy was performed on 18 eyes of 14 patients with closed-angle glaucoma. The intraocular pressure (IOP) was controlled in all but one eye within normal limits. Variable amounts of pigment were found on gonioscopy in all cases. The mydriasis test was positive in one eye (5.5%) after homatropine and in 5 eyes (28%) after tropicamide drops. 80% of the positive results occurred...
متن کاملNew considerations on pupillary block mechanism.
PURPOSE To study the mechanisms of pupillary block in eyes with occludable angle by ultrasound biomicroscopy. METHODS Initially, a pilot study of 13 eyes with acute primary angle-closure without medication was executed. Ultrasound biomicroscopy measurements of the angle, posterior chamber depth and iris thickness were performed in the temporal quadrant under light and dark conditions. Afterwa...
متن کاملAgreement between gonioscopy and ultrasound biomicroscopy in detecting iridotrabecular apposition.
OBJECTIVE To assess the agreement between findings obtained at dark-room gonioscopy and ultrasound biomicroscopy (UBM) in the diagnosis of iridotrabecular apposition in light and dark conditions. METHODS We enrolled patients with appositional angle closure at dark-room gonioscopy performed using a 1-mm slitlamp beam that did not cross the pupil. Ultrasound biomicroscopic images were acquired ...
متن کاملDarkroom prone provocative test in primary angle closure glaucoma relatives.
PURPOSE To evaluate ocular biometric parameters and darkroom prone provocative test (DPPT) in family members of primary angle closure (PAC) glaucoma (PACG) patients and to establish any correlation between these biometric parameters and the DPPT response. METHODS Seventy-four family members of PACG patients underwent ultrasound ocular biometry, slit lamp biomicroscopy, Goldmann applanation to...
متن کاملMechanisms in ocular hypertension.
This paper investigates the hypothesis that intermittent partial angle closure is one of the causes of ocular hypertension. 139 eyes from 76 patients with ocular hypertension were provoked with pilocarpine and phenylephrine. Four distinct responses appeared. Firstly, in 39 eyes (from 24 patients, 32%) gonioscopic closure of part or all of the angle appeared. Secondly, in 30 eyes (from 19 patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 21 شماره
صفحات -
تاریخ انتشار 2007