Analysis of Dosimetric Indices for Evaluating Intensity Modulated Radiotherapy Plans of Head and Neck Cancer Patients

نویسنده

  • Khalid Iqbal
چکیده

To characterize the radiation dose distribution in the target volume, various dosimetric indices are required which assist in making a choice of an optimum treatment plan. This study is primarily aimed at the analysis of various radiation dose indices essential for the evaluation of therapeutic plans by employing Intensity Modulated Radiotherapy (IMRT) on head and neck cancer patients. A group of 20 head and neck cancer patients, who were irradiated with 6MV beam form DHX Varianlinac, were brought into consideration. Their radiotherapy plans were designed using eclipse treatment planning software. Dosimetric indices like homogeneity, mDHI, rDHI, CI of the planning target volumes, were analyzed from the DVH of each patient. All the indices came within the limits as specified by RTOG; 1993 and OLIVER; 2007 except in few cases which might be due to complex geometry, extent of tumor volume and low radiation doses. This exploration can be extended to the calculation of other indices by using beams of higher energy and other treatment techniques on different target volumes of small extent and simple geometry. Research Article Analysis of Dosimetric Indices for Evaluating Intensity Modulated Radiotherapy Plans of Head and Neck Cancer Patients Qurat-ul-ain Shamsi1*, Maria Atiq1, Atia Atiq1, Saeed Ahmad Buzdar1 and Khalid Iqbal2 1The Islamia University of Bahawalpur, Pakistan 2Shaukat Khanum Memorial Cancer Hospital and Research Center, Pakistan

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Validation of the relative insensitivity of volumetric-modulated arc therapy (VMAT) plan quality to gantry space resolution

Volumetric-modulated arc therapy (VMAT) is an efficient form of radiotherapy used to deliver intensity-modulated radiotherapy beams. The aim of this study was to investigate the relative insensitivity of VMAT plan quality to gantry angle spacing (GS). Most previous VMAT planning and dosimetric work for GS resolution has been conducted for single arc VMAT. In this work, a quantitative comparison...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017