Fast gas chromatography of explosive compounds using a pulsed-discharge electron capture detector.

نویسندگان

  • Olivier L Collin
  • Claudia Niegel
  • Kate E Derhodes
  • Bruce R McCord
  • Glen P Jackson
چکیده

The detection of a mixture of nine explosive compounds, including nitrate esters, nitroaromatics, and a nitramine in less than 140 sec is described. The new method employs a commercially available pulsed-discharge electron capture detector (PDECD) coupled with a microbore capillary gas chromatography (GC) column in a standard GC oven to achieve on-column detection limits between 5 and 72 fg for the nine explosives studied. The PDECD has the benefit that it uses a pulsed plasma to generate the standing electron current instead of a radioactive source. The fast separation time limits on-column degradation of the thermally labile compounds and decreases the peak widths, which results in larger peak intensities and a concomitant improvement in detection limits. The combination of short analysis time and low detection limits make this method a potential candidate for screening large numbers of samples that have been prepared using techniques such as liquid-liquid extraction or solid-phase microextraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New fast screening method for organochlorine pesticides in water by using solid-phase microextraction with fast gas chromatography and a pulsed-discharge electron capture detector

A new fast screening method has been developed for the analysis of organochlorine pesticides in water that takes less than 10 min to perform and has detection limits of the order of 10 ng l21. Pesticide extraction was achieved by solid-phase microextraction and the separation was performed using a micro-bore (0.1 mm) capillary column. A laboratory-built cryotrap system was used to focus the ana...

متن کامل

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Analysis of Nitroaromatics and Nitro-Polycyclic Aromatic Hydrocarbons by Capillary Gas Chromatography with the Agilent 6890 Micro-ECD (5965-8015E)

A new electron capture detector (ECD) for the Agilent 6890 Series gas chromatograph (GC) allows very sensitive detection of nitroaromatic compounds at low picogram levels with a linear response over three orders of magnitude. Analysis of Nitroaromatics and Nitro-Polycyclic Aromatic Hydrocarbons by Capillary Gas Chromatography with the Agilent 6890 Micro-ECD This application note describes the p...

متن کامل

Evaluation of the pulsed discharge helium ionization detector for the analysis of hydrogen and methane in breath.

Under the appropriate separation conditions the pulsed discharge helium ionization detector (PDHID) was used to detect hydrogen and methane separated from the matrix components of human breath samples. The sensitivity of this method is over an order of magnitude better than published methods using a flame ionization detector (FID) and a thermal conductivity detector (TCD), and has the further a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of forensic sciences

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 2006