High-efficiency particulate air filter test stand and aerosol generator for particle loading studies.

نویسندگان

  • R Arunkumar
  • Kristina U Hogancamp
  • Michael S Parsons
  • Donna M Rogers
  • Olin P Norton
  • Brian A Nagel
  • Steven L Alderman
  • Charles A Waggoner
چکیده

This manuscript describes the design, characterization, and operational range of a test stand and high-output aerosol generator developed to evaluate the performance of 30 x 30 x 29 cm(3) nuclear grade high-efficiency particulate air (HEPA) filters under variable, highly controlled conditions. The test stand system is operable at volumetric flow rates ranging from 1.5 to 12 standard m(3)/min. Relative humidity levels are controllable from 5%-90% and the temperature of the aerosol stream is variable from ambient to 150 degrees C. Test aerosols are produced through spray drying source material solutions that are introduced into a heated stainless steel evaporation chamber through an air-atomizing nozzle. Regulation of the particle size distribution of the aerosol challenge is achieved by varying source solution concentrations and through the use of a postgeneration cyclone. The aerosol generation system is unique in that it facilitates the testing of standard HEPA filters at and beyond rated media velocities by consistently providing, into a nominal flow of 7 standard m(3)/min, high mass concentrations (approximately 25 mg/m(3)) of dry aerosol streams having count mean diameters centered near the most penetrating particle size for HEPA filters (120-160 nm). Aerosol streams that have been generated and characterized include those derived from various concentrations of KCl, NaCl, and sucrose solutions. Additionally, a water insoluble aerosol stream in which the solid component is predominantly iron (III) has been produced. Multiple ports are available on the test stand for making simultaneous aerosol measurements upstream and downstream of the test filter. Types of filter performance related studies that can be performed using this test stand system include filter lifetime studies, filtering efficiency testing, media velocity testing, evaluations under high mass loading and high humidity conditions, and determination of the downstream particle size distributions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions.

The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expan...

متن کامل

ارزیابی پارامترهای عملکردی در فیلترهای هپا در یک صنعت دارویی(مطالعه موردی1394)

Abstract: Background and aims: Nowadays, cleanrooms have become impartible parts of an industry with sensitive products. Sources of contamination in cleanrooms are impaired performance and quality sensitive products in the cleanrooms .The aim of this study was to evaluate the efficiency of HEPA filter and check the concentration and number of airborne particles in cleanrooms for pharmaceutic...

متن کامل

Filter Performance Degradation of Electrostatic N95 and P100 Filtering Facepiece Respirators by Dioctyl Phthalate Aerosol Loading

Polydisperse dioctyl phthalate (DOP) aerosols are employed for testing filter penetration with loading of Rand P-series particulate filters for National Institute for Occupational Safety and Health (NIOSH) certification. Penetration for filters must not exceed NIOSH allowed maximum levels during the entire loading of 200 mg DOP indicating no filter degradation. Degradation of respirators loaded...

متن کامل

Investigation on the performance of airliner cabin air filter throughout the lifetime usage

The supply air from the airliner ventilation system is a mixture of outside air and recirculated air that passes through a high efficiency particulate air (HEPA) filter. The effectiveness of two commercial-available airliner cabin air filters were investigated under the laboratory-based measurement due to the practical restriction of airliner cabin filter test during usage. The filtration effic...

متن کامل

Factors Influencing HEPA Filter Performance – 9060

Properly functioning HEPA air filtration systems depend on a variety of factors that start with the use of fully characterized challenge conditions for system design and then process control during operation. This paper addresses factors that should be considered during the design phase as well as operating parameters that can be monitored to ensure filter function and lifetime. HEPA filters us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 78 8  شماره 

صفحات  -