Experimental investigation on the influencing factors of a transcritical CO2 heat pump

نویسندگان

  • J. L. Ma
  • Y. Hou
چکیده

As one of the earliest natural refrigerants, CO2 has a lot of unique advantages, such as zero ODP, negligible GWP, excellent heat transfer coefficient, high volumetric capacity, non-toxicity, non-flammability, and cost effectiveness. Since it was proposed to applying in the mobile air-conditioning, the transcritical CO2 cycle has been attracting great attentions to replace CFC and HCFC refrigerants in many areas, including refrigeration, heat pump, and airconditioning, etc.Unlike the conventional refrigerants, the heat rejection pressure and temperature of the gas-cooler in the transcritical cycle are usually decoupled in the transcritical cycle. Besides, there exists an optimal heat rejection pressure under which the maximum cycle efficiency can be achieved. The concept of “the optimal heat rejection pressure” has attracted wide attentions in the scientific community. Therefore, the interaction effect between heat rejection pressure and system performance has been studied by many researchers.The heat rejection pressure of the gas-cooler has a great impact on the COP of the transcritical CO2 system, but the investigation on the influence factors of the heat rejection pressure is quite rare in the open literature. In this paper, the effects of the water inlet temperatures and the water flow rates on the heat rejection pressure of a water-to-water transcritical CO2 refrigeration heat pump with single-stage expansion system have been investigated. Furthermore, the operation parameters and the performance of the system are also evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation on the Influence of Refrigerant Charge on the Performance of Trans-critical CO2 Water-Water Heat Pump

For the environmentally aware, natural refrigerant such as CO2 is recommended and pursued by researchers for refrigerators. In this paper, a transcritical CO2 heat pump system was set up to investigate the influence of refrigerant charge on the performance of a small-sized heat pump water heater. The transcritical CO2 heat pump system was composed of a rotary compressor, a tube-in-tube evaporat...

متن کامل

Experimental Study on the Heating Performance of a CO2 Heat Pump with Gas Injection

With the increasing of the environmental concerns, carbon dioxide (CO2) as an alternative refrigerant has been investigated intensively. In this study, the heating performance of a transcritical CO2 heat pump system with a twinrotary compressor was investigated. The transcritical CO2 heat pump with gas injection was tested by varying gas injection ratio and outdoor temperature at the optimum re...

متن کامل

Performance of a Transcritical CO2 Heat Pump for Simultaneous Water Cooling and Heating

This paper presents the experimental as well as the simulated performance studies on the transcritical CO2 heat pumps for simultaneous water cooling and heating; effects of water mass flow rates and water inlet temperatures of both evaporator and gas cooler on the cooling and heating capacities, system COP and water outlets temperatures are investigated. Study shows that both the water mass flo...

متن کامل

Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater

Besides compressor rotary speed and parameters of water flowing through gas cooler and evaporator, refrigerant charge amount and electronic expansion valve (EEV) opening are two important parameters that have significant effects on the performance of a transcritical CO2 heat pump system. In this study, the effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump ...

متن کامل

Transcritical Carbon Dioxide Microchannel Heat Pump Water Heaters: Part II - System Simulation and Optimization

This paper presents the development of a transcritical CO2 heat pump water heating system model incorporating analytical heat exchanger models and an empirical compressor model. This study investigated the effects of a suction line heat exchanger (SLHX) and once-through versus multi-pass water heating schemes. The once-through systems outperformed the multi-pass systems by 10% for the system wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014