Frequency of the first heart sound in the assessment of stiffening of mitral bioprosthetic valves.

نویسندگان

  • P D Stein
  • H N Sabbah
  • J B Lakier
  • D J Magilligan
  • D Goldstein
چکیده

The frequency spectrum of the first heart sound (S1) was measured noninvasively in 54 patients with porcine bioprosthetic valves inserted in the mitral position. Phonocardiograms were recorded on magnetic tape on line with a signal processor with which the frequency spectrum and peak frequency of S1 were determined. In 19 patients with normal natural mitral valves, the apparent peak frequency within the range of measured frequencies of S1 was 46 +/- 2 Hz (mean +/- SEM). In 11 patients with porcine bioprosthetic valves implanted in the mitral position for less than or equal to 11/2 years, the apparent peak frequency of S1 was 43 +/- 3 Hz, which was not significantly different from S1 in patients with normal mitral valves. However, in 33 patients with porcine bioprosthetic valves in place 5-7 years, the apparent peak frequency of S1 was higher, 67 +/- 2 Hz (p < 0.001). In patients in whom the porcine bioprosthetic valve was implanted 5 years or longer, the frequency spectrum of S1 showed a greater proportion of sound energy at frequencies between 50-200 Hz compared with patients in whom the prosthetic valve was implanted 11/2 years or less. changes of the frequency of S1 in these patients may be a manifestation of stiffening of the valve as a result of early degenerative changes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibrational analysis of bioprosthetic heart valve leaflets using numerical models: effects of leaflet stiffening, calcification, and perforation.

The fundamental natural frequency of the closed cusps of porcine bioprosthetic valves, fabricated from the normal leaflets of pig aortic valves, was estimated using a finite element model. Both normal and stiffened leaflets were considered in the vibrational analysis. The effects of conditions that simulated degeneration, such as stiffening, central perforation, a tear, calcium deposits in the ...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.

One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...

متن کامل

بررسی 290 کودک مبتلا به بیماری دریچه‌ای قلبی روماتیسمی

    Background & Aim: Acute rheumatic fever and its cardiac involvement is one of the most prevalent acquired pediatric heart diseases in developing countries needing long hospitalization, cardiac surgery, prophylaxis, and delicate management and causing death in some cases. A paucity of information about this disease in our country made us perform the present study in one of the largest pediat...

متن کامل

Pregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves

There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 63 1  شماره 

صفحات  -

تاریخ انتشار 1981