Comparison of a GE Lunar DPX-IQ and a Norland XR-26 dual energy X-ray absorptiometry scanner for body composition measurements in pigs – in vivo
نویسندگان
چکیده
In the context of future growth and performance testing, this study compares corresponding body composition results measured by two dual energy X-ray absorptiometry systems. To test the capability of each device to detect differences among experimental groups widely varying in body composition, 77 pigs from 6 purebred/crossbred groups were used for the experiment. Each pig was scanned consecutively on a Norland XR-26 and on a GE Lunar DPX-IQ. Coefficients of determination were: R2=0.92 for bone mineral content (BMC), R2=0.90 for bone mineral density (BMD), R2=0.94 for lean mass (LEAN), R2=0.92 for fat mass (FAT), R2=0.88 for lean percentage (%LEAN) and fat percentage (%FAT). However, Norland yielded larger values for %FAT and smaller values for %LEAN, BMC, and BMD than Lunar (P<0.001) with the extent of deviation depending on the specific trait and on the breeding group. The deviation in BMC was greater than the deviation in BMD, suggesting different bone detecting algorithms. Both systems revealed similar differences among the breeding groups, and ranked them in the same order based on numerical values. Differences in calibration, bone detection, and software algorithms, however, require a prior crosscalibration to make the body composition data from both systems directly comparable. Finally, they can be used across research centres for the determination of relative and absolute body composition differences among animal groups and individuals.
منابع مشابه
Evaluation of a new body composition phantom for quality control and cross-calibration of DXA devices.
This study evaluated a new body composition phantom and its use for quality control and cross-calibration of dual-energy X-ray absorptiometry (DXA) instruments for measurements of body composition. We imaged the variable composition phantom (Lunar, Madison, WI) on eight different DXA devices. Deviations of up to 7% fat were observed when we compared the percent fat values measured by the differ...
متن کاملNon-invasive determination of body composition in pigs using a Norland XR-26 bone densitometer
Non-invasive measurement of body composition provides advantages in growth studies compared to conventional techniques. The same individual can be measured several times, the measurement is faster, and the number of pigs required as well as the random effect of animal are reduced. The aim of the present study was to determine the composition of the half carcass and of the ham/shank region by a ...
متن کاملCross-calibration of fat and lean measurements by dual-energy X-ray absorptiometry to pig carcass analysis in the pediatric body weight range.
The objective of this study was to cross-calibrate measurements of body composition by dual-energy X-ray absorptiometry (DXA) with chemical analysis of carcasses of pigs in the pediatric range of body weight. Eighteen pigs (25.5 +/- 7.0 kg; 9.9-32.8% body fat) were scanned in duplicate by using DXA with a Lunar DPX-L densitometer in the pediatric medium and adult fast-detail scan modes. Pigs we...
متن کاملComparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملComparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis
Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...