Preference of undergraduate students after first experience on nickel-titanium endodontic instruments

نویسندگان

  • Sang Won Kwak
  • Gary Shun-Pan Cheung
  • Jung-Hong Ha
  • Sung Kyo Kim
  • Hyojin Lee
  • Hyeon-Cheol Kim
چکیده

OBJECTIVES This study aimed to compare two nickel-titanium systems (rotary vs. reciprocating) for their acceptance by undergraduate students who experienced nickel-titanium (NiTi) instruments for the first time. MATERIALS AND METHODS Eighty-one sophomore dental students were first taught on manual root canal preparation with stainless-steel files. After that, they were instructed on the use of ProTaper Universal system (PTU, Dentsply Maillefer), then the WaveOne (WO, Dentsply Maillefer). They practiced with each system on 2 extracted molars, before using those files to shape the buccal or mesial canals of additional first molars. A questionnaire was completed after using each file system, seeking students' perception about 'Ease of use', 'Flexibility', 'Cutting-efficiency', 'Screwing-effect', 'Feeling-safety', and 'Instrumentation-time' of the NiTi files, relative to stainless-steel instrumentation, on a 5-point Likert-type scale. They were also requested to indicate their preference between the two systems. Data was compared between groups using t-test, and with Chi-square test for correlation of each perception value with the preferred choice (p = 0.05). RESULTS Among the 81 students, 55 indicated their preferred file system as WO and 22 as PTU. All scores were greater than 4 (better) for both systems, compared with stainless-steel files, except for 'Screwing-effect' for PTU. The scores for WO in the categories of 'Flexibility', 'Screwing-effect', and 'Feeling-safety' were significantly higher scores than those of PTU. A significant association between the 'Screwing-effect' and students' preference for WO was observed. CONCLUSIONS Novice operators preferred nickel-titanium instruments to stainless-steel, and majority of them opted for reciprocating file instead of continuous rotating system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of cryogenic treatment on nickel-titanium endodontic instruments.

AIM To investigate the effects of cryogenic treatment on nickel-titanium endodontic instruments. The null hypothesis was that cryogenic treatment would result in no changes in composition, microhardness or cutting efficiency of nickel-titanium instruments. METHODOLOGY Microhardness was measured on 30 nickel-titanium K-files (ISO size 25) using a Vicker's indenter. Elemental composition was me...

متن کامل

Detection of Procedural Errors with Stainless Steel and NiTi Instruments by Undergraduate Students Using Conventional Radiograph and Cone Beam Computed Tomography

INTRODUCTION This study investigated procedural errors made during root canal preparation using stainless steel and nickel-titanium (NiTi) instruments by undergraduate students, using two diagnostic imaging methods. MATERIALS AND METHODS Sixty human molars were divided into three groups (n=20; group 1: K-Flexofile, group 2: K3, and group 3: BioRace). The root canals were filled with gutta-per...

متن کامل

Assessment of the Effect of the Ionic Implantation by Plasma Immersion on the Flexibility of the Nickel-titanium Endodontic Fi

Due to its pseudo elastic behavior, the nickel-titanium (nitinol) alloy has been used in the manufacture of endodontic instruments in recent years, being especially useful for curved canals preparation. Extensive research has been carried out to improve the wear resistance of the nitinol instruments without create modifications in the bulk of the files. The purpose of this work was to measure t...

متن کامل

An overview of the mechanical properties of nickeltitanium endodontic instruments

Differences in mechanical properties between endodontic instruments might be related to the chemical composition, phase constitution, or fabrication process of nickel–titanium (NiTi) endodontic instruments. An awareness and knowledge of the mechanical properties of NiTi endodontic files and their association with the metallurgical properties is useful for clinicians to understand the behavior o...

متن کامل

Comparison of postoperative pain after root canal treatment using reciprocating instruments based on operator’s experience: A prospective clinical study

BACKGROUND The aim of the present study was to compare clinically the incidence of postoperative pain after endodontic treatment using the Reciproc System, taking into account the operator's experience. MATERIAL AND METHODS One hundred patients scheduled for routine endodontic treatment were enrolled in this study. Endodontic treatment was carried out in a single visit by undergraduate and po...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2016