Cause of apical thinning on attenuation-corrected myocardial perfusion SPECT.

نویسندگان

  • Koichi Okuda
  • Kenichi Nakajima
  • Shinro Matsuo
  • Hiroshi Wakabayashi
  • Junichi Taki
  • Seigo Kinuya
چکیده

OBJECTIVES Decreases in apical and apex activities - namely, 'apical thinning' - are a well-known phenomenon in attenuation-corrected (AC) myocardial perfusion. The aim of this study was to compare actual myocardial thickness derived from a multidetector-row computed tomography with AC myocardial perfusion count from a hybrid single-photon emission computed tomography/computed tomography to investigate the cause of apical thinning. METHODS We enrolled 21 participants with a low likelihood of coronary artery disease (mean age 65 ± 21 years, 13 men) from 185 consecutive patients and 11 healthy volunteers, who independently underwent ⁹⁹mTc-sestamibi single-photon emission computed tomography/computed tomography and 64-slice multidetector-row computed tomography scans. AC and non-AC myocardial perfusion counts and thickness were measured on the basis of a 17-segment model and averaged at the apex, apical, mid, and basal walls. RESULTS Myocardial thickness at the apex was significantly thinner than that at the apical and mid walls (5.1 ± 1.3, 7.3 ± 1.3, and 9.9 ± 2.4 mm, respectively; P<0.005). AC count at the apex was significantly lower than that at the apical and mid regions (76.0 ± 5.5, 82.8 ± 4.7, and 85.6 ± 3.8, respectively; P<0.002). Moderate relationship was observed between myocardial thickness and AC count (y=-10.5 + 0.22x, r=0.54, P<0.0001. No relationship was found between thickness and non-AC count (r=0.16, P=0.263). CONCLUSION The low apex and apical counts were caused by anatomical thinning of the myocardium in AC myocardial perfusion imaging. Attenuation correction provided an accurate relationship between myocardial count and thickness because of the partial volume effect.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT Introduced by misalignment between emission scan and CT-derived attenuation maps.

UNLABELLED Nonuniform soft-tissue attenuation affects the diagnostic accuracy of SPECT in myocardial perfusion imaging. The attenuation map required for attenuation correction can be acquired using x-ray tomography (CT). Frequent findings in attenuation-corrected images are defects in the apical and anterior myocardial wall. We assume that these are artifacts produced by misalignment of SPECT i...

متن کامل

Diffuse bilateral breast uptake on the myocardial perfusion SPECT of a nursing female

  Bilateral diffuse intense breast uptake was noted in a 40 year old female who was evaluated with Tc-99m sestamibi (MIBI) myocardial perfusion scan for possible ischemia. She was breast feeding her 1.5 year old child. The intense uptake in the breasts was superimposed on the apical and anteroapical regions of the myocardium and caused interpretation problem. We recom...

متن کامل

The value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]

Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nuclear medicine communications

دوره 32 11  شماره 

صفحات  -

تاریخ انتشار 2011