A swine model to analyze arterial structural changes induced by mechanical thrombectomy.
نویسندگان
چکیده
We report a novel swine model that allows direct visualization of cervical arteries undergoing mechanical thrombectomy. The model also facilitates evaluation of histologic changes observed in the arteries after treatment. Swine superficial cervical arteries, which are similar in size and branching pattern to the human middle cerebral artery, were surgically exposed, occluded with experimental thrombus, and subsequently treated with the Merci clot retriever device. Angiographic and histologic assessment were performed.
منابع مشابه
A novel method of thrombus preparation for use in a swine model for evaluation of thrombectomy devices.
We report the development of a novel technique of thrombus preparation for use in a swine model for evaluation of thrombectomy devices. The experimental thrombus prepared using plain sedimentation showed mechanical stability due to its solid fibrin-rich component. The thrombus also showed histologic similarity to the typical thromboemboli recovered from patients with stroke in the course of the...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملForced Arterial Suction Thrombectomy Using Distal Access Catheter in Acute Ischemic Stroke
Historical innovations in mechanical thrombectomy devices and strategies for ischemic stroke have resulted in improved angiographic outcomes and better clinical outcomes. Various devices have been used, but the two most common approaches are aspiration thrombectomy and stent-retrieval thrombectomy. Aspiration thrombectomy has advanced from the traditional Penumbra system to forced arterial suct...
متن کاملIn vivo evaluation of the Phenox CRC mechanical thrombectomy device in a swine model of acute vessel occlusion.
BACKGROUND AND PURPOSE Mechanical thrombectomy in ischemic stroke is of increasing interest as it is a promising strategy for fast and efficient recanalization. Several thrombectomy devices have been introduced to the armentarium of mechanical thrombectomy. Currently, new devices are under development and are continuously added to the neurointerventional tool box. Each device advocated so far h...
متن کاملA dedicated animal model for mechanical thrombectomy in acute stroke.
BACKGROUND Recent studies have focused on mechanical thrombectomy as a means to reduce the time required for revascularization and increase the revascularization rate in acute stroke. To date no systematic evaluation has been made of the different mechanical devices in this novel and fast-developing field of endovascular interventions. To facilitate such evaluations, we developed a specific in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 34 8 شماره
صفحات -
تاریخ انتشار 2013