New pulse wave measurement method using different hold-down wrist pressures according to individual patient characteristics
نویسندگان
چکیده
In traditional Chinese and Korean medicine, doctors first observe a patient's pulse by gently and strongly pressing their fingers onto the wrist, and then make a diagnosis based on the observed pulse waves. The most common method to implement this diagnostic technique is to mechanically extract the pulse waves by applying a fixed range of pressures for all patients. However, this method does not consider the patients individual characteristics such as age, sex, and skin thickness. In the present study, we propose a new method of pulse wave extraction that incorporates the personal characteristics of the patients. This method measures the pulse wave signal at varying hold-down pressures, rather than applying a fixed hold-down pressure for all patients. To compare this new technique with existing methods, we extracted pulse waves from 20 subjects, and then determined the actual applied pressure at each step, the coefficient of floating and sinking pulse (CFS), and the distinction of floating/sinking pulse for each group. Consequently, each subject had a different pressure range in our proposed method, whereas all subjects had a similar pressure range in the existing method. Four of 20 subjects exhibited different floating/sinking pulse patterns due to the value of the first pressure step and the range of hold-down pressures. These four subjects were categorized as overweight based on BMI. In addition, the moving distance of the proposed method was longer than the existing method (p = 0.003, paired t-test), and the correlation coefficient between CFS values of two different methods was 0.321, indicating that there was no correlation.
منابع مشابه
Piezoelectric sensor determination of arterial pulse wave velocity.
Arterial pulse wave velocity (APWV) is a measure of the elasticity (or stiffness) of peripheral arterial blood vessels. The pulse referred to here will be the pressure pulse as opposed to the flow pulse measured by ultrasound Doppler. The pressure pulse velocity varies over the range from about 12 m s(-1) to 15 m s(-1) in stiff peripheral arteries, whereas in normal arteries it has a velocity i...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
متن کاملDesigning and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
متن کاملتخمین بدون کاف فشارخون مبتنی بر ویژگیهای زمانی سیگنال نبض
Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...
متن کاملSelf-mixing Interferometry and Its Applications in Noninvasive Pulse Detection
This thesis describes the laser Doppler technique based on a self-mixing effect in a diode laser to noninvasive cardiovascular pulse detection in a human wrist above the radial artery. The main applications of self-mixing interferometry described in this thesis in addition to pulse detection are arterial pulse shape and autonomic regulation measurements. The elastic properties of the arterial w...