Photoacoustic Imaging of Breast Microcalcifications: A Preliminary Study with 8-Gauge Core-Biopsied Breast Specimens
نویسندگان
چکیده
BACKGROUND We presented the photoacoustic imaging (PAI) tool and to evaluate whether microcalcifications in breast tissue can be detected on photoacoustic (PA) images. METHODS We collected 21 cores containing microcalcifications (n = 11, microcalcification group) and none (n = 10, control group) in stereotactic or ultrasound (US) guided 8-gauge vacuum-assisted biopsies. Photoacoustic (PA) images were acquired through ex vivo experiments by transmitting laser pulses with two different wavelengths (700 nm and 800 nm). The presence of microcalcifications in PA images were blindly assessed by two radiologists and compared with specimen mammography. A ratio of the signal amplitude occurring at 700 nm to that occurring at 800 nm was calculated for each PA focus and was called the PAI ratio. RESULTS Based on the change of PA signal amplitude between 700 nm and 800 nm, 10 out of 11 specimens containing microcalcifications and 8 out of 10 specimens without calcifications were correctly identified on blind review; the sensitivity, specificity, accuracy, positive predictive and negative predictive values of our blind review were 90.91%, 80.0%, 85.71%, 83.33% and 88.89%. The PAI ratio in the microcalcification group was significantly higher than that in the control group (the median PAI ratio, 2.46 versus 1.11, respectively, P = .001). On subgroup analysis in the microcalcification group, neither malignant diagnosis nor the number or size of calcification-foci was proven to contribute to PAI ratios. CONCLUSION Breast microcalcifications generated distinguishable PA signals unlike breast tissue without calcifications. So, PAI, a non-ionizing and non-invasive hybrid imaging technique, can be an alternative in overcoming the limitations of conventional US imaging.
منابع مشابه
Benign papillomas diagnosed on large-gauge vacuum-assisted core needle biopsy which span <1.5 cm do not need surgical excision.
The objective of our study is to determine if a carefully selected subset of benign breast papillomas (size ≤1.5 cm) can be safely followed by imaging surveillance instead of immediate surgical excision. Over a 6½-year period, 86 breast lesions were diagnosed as a benign papilloma (BP) utilizing an 11- or 8-gauge vacuum-assisted core needle biopsy (VACNB) device. In general, it was our intent t...
متن کاملBreast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome.
PURPOSE To retrospectively determine the frequency and causes of failure to retrieve microcalcifications in nonpalpable lesions, as judged on a radiograph of the specimen, and to determine outcome in patients with those lesions. MATERIALS AND METHODS Informed consent was obtained from each patient prior to biopsy. The institutional review board approved this HIPAA-compliant study and granted ...
متن کاملImprint cytology on microcalcifications excised by Vacuum-Assisted Breast Biopsy: A rapid preliminary diagnosis
BACKGROUND To evaluate imprint cytology in the context of specimens with microcalcifications derived from Vacuum-Assisted Breast Biopsy (VABB). PATIENTS AND METHODS A total of 93 women with microcalcifications BI-RADS 3 and 4 underwent VABB and imprint samples were examined. VABB was performed on Fischer's table using 11-gauge Mammotome vacuum probes. A mammogram of the cores after the proced...
متن کاملUltrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions
PURPOSE To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). MATERIALS AND METHODS Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guide...
متن کامل[Sonographic detection of microcalcifications - potential of new method].
PURPOSE Does the easier microcalcification detection (EMD) method enable sonographic visualization of microcalcifications in breast core biopsy specimens compared with mammography? MATERIALS AND METHODS In a prospective randomized study, 105 core biopsy specimens obtained with stereotactic guidance were examined by mammography and ultrasound. EMD is integrated in a high-end ultrasound system ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014