Fast T2-weighted MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts.
نویسندگان
چکیده
The purpose of this study was to quantitatively evaluate in a phantom model the practical impact of alteration of key imaging parameters on image quality and artifacts for the most commonly used fast T(2)-weighted MR sequences. These include fast spin-echo (FSE), single shot fast spin-echo (SSFSE), and spin-echo echo-planar imaging (EPI) pulse sequences. We developed a composite phantom with different T1 and T2 values, which was evaluated while stationary as well as during periodic motion. Experiments involved controlled variations in key parameters including effective TE, TR, echo spacing (ESP), receive bandwidth (BW), echo train length (ETL), and shot number (SN). Quantitative analysis consisted of signal-to-noise ratio (SNR), image nonuniformity, full-width-at-half-maximum (i.e., blurring or geometric distortion) and ghosting ratio. Among the fast T(2)-weighted sequences, EPI was most sensitive to alterations in imaging parameters. Among imaging parameters that we tested, effective TE, ETL, and shot number most prominently affected image quality and artifacts. Short T(2) objects were more sensitive to alterations in imaging parameters in terms of image quality and artifacts. Optimal clinical application of these fast T(2)-weighted imaging pulse sequences requires careful attention to selection of imaging parameters.
منابع مشابه
Optimal Pulse Sequence for Ferumoxides-Enhanced MR Imaging Used in the Detection of Hepatocellular Carcinoma: A Comparative Study Using Seven Pulse Sequences
OBJECTIVE To identify the optimal pulse sequence for ferumoxides-enhanced magnetic resonance (MR) imaging in the detection of hepatocelluar carcinomas (HCCs). MATERIALS AND METHODS Sixteen patients with 25 HCCs underwent MR imaging following intravenous infusion of ferumoxides. All MR studies were performed on a 1.5-T MR system, using a phased-array coil. Ferumoxides (Feridex IV) at a dose of...
متن کاملSpinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.
PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کامل1.5 versus 3 versus 7 Tesla in abdominal MRI: A comparative study
OBJECTIVES The aim of this study was to investigate and compare the feasibility as well as potential impact of altered magnetic field properties on image quality and potential artifacts of 1.5 Tesla, 3 Tesla and 7 Tesla non-enhanced abdominal MRI. MATERIALS AND METHODS Magnetic Resonance (MR) imaging of the upper abdomen was performed in 10 healthy volunteers on a 1.5 Tesla, a 3 Tesla and a 7...
متن کاملFast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.
OBJECTIVE The purpose of this study was to optimize a new rapid-acquisition MR pulse sequence, called fast multiplanar spoiled gradient-recalled (FMPSPGR) imaging, for breath-hold imaging of the liver and to compare unenhanced and contrast-enhanced FMPSPGR with standard spin-echo imaging in detecting liver tumors. MATERIALS AND METHODS The pulse sequence was optimized at 1.5 T with a healthy ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance imaging
دوره 21 7 شماره
صفحات -
تاریخ انتشار 2003