A Dosimetric Comparison of Intensity-Modulated Proton Therapy, Volumetric-Modulated Arc Therapy, and 4π Non-Coplanar Intensity-Modulated Radiation Therapy for a Patient with Parameningeal Rhabdomyosarcoma

نویسندگان

  • Tiffany W Chen
  • Julian Sison
  • Becky Lee
  • Arthur J Olch
  • Andrew Chang
  • Annelise Giebeler
  • Kenneth Wong
چکیده

Rhabdomyosarcoma (RMS) is the most common soft tissue sarcoma in children and manifests as two major histological subtypes: embryonal and alveolar. The five-year local failure rate for RMS at parameningeal sites (middle ear, mastoid region, nasal cavity, etc.) is around 17% despite multiple Intergroup Rhabdomyosarcoma Study Group (IRS) trials conducted to determine the optimal radiation treatment regimen. This case report explores the use of intensity-modulated proton therapy (IMPT) for a 10-year-old child who presented with left eye irritation, facial pain, and headaches and was found to have an alveolar parameningeal rhabdomyosarcoma. He received systemic therapy as well as radiation therapy to 5,640 cGy and 4,320 cGy over 24 fractions, prescribed for gross tumor extension and adjacent high-risk involved sites, respectively, via simultaneous integrated boost. Approximately two years following treatment, the patient has had no recurrence of his RMS with no distant metastases. In addition, his presenting symptom of left eye irritation has improved. His only side effect from radiation at this point is short stature, possibly due to growth hormone deficiency. The patient's IMPT plan was compared with volumetric-modulated arc therapy (VMAT) and 4π non-coplanar intensity-modulated radiation therapy (IMRT) plans, and comparisons of isodose lines show decreased dose to the distal brain tissue with preserved target conformality by IMPT. IMPT also allowed for increased sparing of the patient's retina, lens, and lacrimal gland. All radiation plans achieved conformal dose coverage to the planning/scanning target volumes, while the IMPT plan is potentially better at sparing the patient from developing long-term optic apparatus side effects and neurocognitive defects. In this case, IMPT is comparable, if not favorable, when long-term side effects can be reduced while maintaining dose conformality and local control.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases

BACKGROUND Intensity-modulated proton therapy (IMPT), non-coplanar 4π intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate cancer treatment. METHODS Ten prostate patients were planned using IMPT with robustness optimizat...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017