Simultaneous in vivo spectral editing and water suppression.
نویسندگان
چکیده
Water suppression is typically performed in vivo by exciting the longitudinal magnetization in combination with dephasing, or by using frequency-selective coherence generation. MEGA, a frequency-selective refocusing technique, can be placed into any pulse sequence element designed to generate a Hahn spin-echo or stimulated echo, to dephase transverse water coherences with minimal spectral distortions. Water suppression performance was verified in vivo using stimulated echo acquisition mode (STEAM) localization, which provided water suppression comparable with that achieved with four selective pulses in 3,1-DRYSTEAM. The advantage of the proposed method was exploited for editing J-coupled resonances. Using a double-banded pulse that selectively inverts a J-coupling partner and simultaneously suppresses water, efficient metabolite editing was achieved in the point resolved spectroscopy (PRESS) and STEAM sequences in which MEGA was incorporated. To illustrate the efficiency of the method, the detection of gamma-aminobutyric acid (GABA) was demonstrated, with minimal contributions from macromolecules and overlying singlet peaks at 4 T. The estimated occipital GABA concentration was consistent with previous reports, suggesting that editing for GABA is efficient when based on MEGA at high field strengths.
منابع مشابه
Artefact minimized spectral editing at 7T: quick and accurate in-vivo detection of GABA
Introduction: Spectral editing techniques are used in MRS to improve the detection of low concentrated metabolites like GABA [1], of which signals are overlapped with resonances of other highly concentrated compounds, such as Creatine and macromolecules. However, these methods rely on subtraction of two in vivo MR spectra and, therefore, are prone to artefacts. MRS at high field benefits from h...
متن کاملB0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy.
The homogenization of B0 conditions is necessary for every magnetic resonance spectroscopy (MRS) investigation. Its direct consequence is narrow spectral lines, on which reliable separation and quantification of biochemicals, and thus experimentally obtainable metabolic information, fundamentally relies. Besides spectral linewidth, unwanted B0 inhomogeneity also impairs other aspects of the MRS...
متن کاملGABA editing at 3T with Macromolecule Suppression: MEGA-SPECIAL
Introduction. One commonly used method for in-vivo magnetic resonance spectroscopy (MRS) detection of γ-aminobutyric acid (GABA) is the MEGA-PRESS technique [1], which enables direct observation of the GABA resonance at 3.02 ppm. Unfortunately, direct quantification of GABA using MEGA-PRESS is complicated by co-editing of macromolecule (MM) signals, which also resonate at 3.02 ppm [2]. Two meth...
متن کاملINS-PRESS for functional MRS: simultaneous with- and without-water suppression spectral acquisition on visual cortex of human brains at 3T
Fig 2. (a) Time courses of total NAA, choline, creatine and mI during the paradigm of 6.4-mins stimulation as in Fig 1(a). (b) Time courses of these four metabolites used the stimulation paradigm as in Fig 1(b). These spectra were quantitated after 32 scan averages. Error bars show the inter-subject standard deviations. INS-PRESS for functional MRS: simultaneous withand without-water suppressio...
متن کاملOptimized selective lactate excitation with a refocused multiple-quantum filter.
Selective detection of lactate signals in in vivo MR spectroscopy with spectral editing techniques is necessary in situations where strong lipid or signals from other molecules overlap the desired lactate resonance in the spectrum. Several pulse sequences have been proposed for this task. The double-quantum filter SSel-MQC provides very good lipid and water signal suppression in a single scan. ...