Stable Isotope Dilution Assay Mass Spectrometry in Flavour Research: Internal Standard and Calibration Issues

نویسندگان

  • L. B. Fay
  • S. Metairon
چکیده

Mass spectrometry is widely used in flavour research to quantify compounds by using isotopically labelled internal standards. However, equimolar amounts of different molecules do not give equal instrumental responses. Therefore, calibration of the mass spectrometer is needed prior to any sample quantification. If the mass of the internal standard differs from that of the analyte by more than 3 Da, the calibration curve is linear. If this mass difference is lower, a second-order curve is obtained that can be linearised by applying various mathematical treatments. We tested a number of linearisation techniques and recommend the method that uses isotopic enrichment calculation to control the quality of the mass spectrometer’s calibration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous analysis of phthalates, adipate and polycyclic aromatic hydrocarbons in edible oils using isotope dilution-gas chromatography-mass spectrometry.

A method for simultaneous determination of 12 priority phthalates, adipate and polycyclic aromatic hydrocarbons (PAHs) in edible oils by isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) was developed for fast, accurate and trace analysis. The extraction and clean-up procedures were optimised, and using stable isotope-labelled internal standards for each analyte, relative standar...

متن کامل

Determination of creatinine in human urine with flow injection tandem mass spectrometry.

BACKGROUND/AIMS Excretion of urinary compounds in spot urine is often estimated relative to creatinine. For the growing number of liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays of urine-excreted molecules, a fast and accurate method for determination of creatinine is needed. METHODS A high-throughput flow injection tandem mass spectrometry method for exact quantitation of cr...

متن کامل

Evaluation of minimal 13C-labelling for stable isotope dilution in organic analysis.

A procedure for Stable Isotope Dilution Analysis in molecular Mass Spectrometry which does not require a methodological calibration graph and can be applied in combination with minimal labelling has been evaluated. This alternative approach is based on the determination of the molar fractions for each pure isotope pattern (natural abundance or labelled) contributing to the isotope pattern obser...

متن کامل

Target analyte quantification by isotope dilution LC-MS/MS directly referring to internal standard concentrations--validation for serum cortisol measurement.

BACKGROUND Isotope dilution LC-MS/MS methods used in the clinical laboratory typically involve multi-point external calibration in each analytical series. Our aim was to test the hypothesis that determination of target analyte concentrations directly derived from the relation of the target analyte peak area to the peak area of a corresponding stable isotope labelled internal standard compound [...

متن کامل

Use of inductively coupled plasma-mass spectrometry in boron-10 stable isotope experiments with plants, rats, and humans.

The commercial availability of inductively coupled plasma-mass spectrometry technology (ICP-MS) has presented the opportunity to measure the boron concentrations and isotope ratios in a large number of samples with minimal sample preparation. A typical analytical sequence for fecal samples consists of 25 acid blanks, 1 digestion blank, 5 calibration solutions, 4 standard reference material solu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001