A Simplified Droop Method Implementation in Parallel Ups Inverters with Proportional-resonant Controller

نویسنده

  • H. MOKHTARI
چکیده

In this paper, a simpler implementation of the well-known droop method for the control of parallel Uninterruptible Power Supply (UPS) systems is presented. In this method, in the power-sharing control scheme, the output current is calculated by software without the need for a current sensor, resulting in a simpler and cheaper structure. By doing so, the number of feedback sensors is reduced from three to two. The paralleling strategy uses the droop method in which the control strategy is based on the drop in the inverter output frequency and amplitude. The application of Proportional-Resonant (PR) controllers is also extended to parallel inverter and its superior performance over the well-known Proportional-Integral-Derivative (PID) controller is shown. To show the performance of the proposed system, a system of two-parallel connected UPS is simulated, and two types of linear and non-linear loads are considered. The non-linear load is compliant with the IEC 62040-3 standard for class I UPS. The results show that the reduction of sensors results in no error, and the control system performance is quite satisfactory. To verify the proposed concept, a two-625VA UPS system is implemented. Several tests on both linear and non-linear loads are performed and the results, which are in good agreement with those of the simulations, are provided. The results indicate that the proposed parallel inverter control structure provides a better system in terms of performance parameters. Keywords– Uninterruptible power supply (UPS), droop control method, proportional-resonant (PR) controller

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reactive Power Sharing and Harmonic Voltage Modification in Single Phase Island Micro-Grid with Drop Control

Abstract: When several parallel inverters are in islands operating mode, the droop control scheme is usually used to control the inverters. The droop control method enables the inverters of a Micro-Grid to control the voltage and frequency of the network in a decentralized regulation behavior. The drop control method also enables the inverters to share the required active and reactive powers of...

متن کامل

Design and Analysis of the Droop-Controlled Parallel Four-leg Inverters to Share Unbalanced and Nonlinear Loads

In this paper, the performance of wireless operation of four-leg parallel inverters, at the presence of unbalanced nonlinear loads, is investigated. In order to control the parallel inverters, an inner current and external voltage control loops should be designed. In this paper, a proportional controller for the current internal loop as well as a proportional-resonant one for the voltage extern...

متن کامل

Bounded droop controller for parallel operation of inverters

In this paper, the stability of parallel-operated inverters in the sense of boundedness is investigated. At first, the non-linear model of parallelled inverters with a generic linear or non-linear load is obtained by using the generalised dissipative Hamiltonian structure and then the robust droop controller, recently proposed in the literature for parallel operation of inverters, is implemente...

متن کامل

A Modified Droop Controller for Parallel Operation of Single-Phase Inverters in Islanded Microgrid

Conventional droop control is a basic control strategy for power sharing in islanded microgrid applications. This strategy has several limitations, such as low transient response, frequency and voltage deviations. This paper presents a modified droop control method for the proper operation of parallel-connected inverters in islanded microgrid. The proposed method is able to improve transient re...

متن کامل

Voltage Imbalance Compensation for Droop-Controlled Inverters in Islanded Microgrid

In this paper, a new control strategy is proposed for implementation in low-voltage microgrids with balanced/ unbalanced load circumstances. The proposed scheme contains, the power droop controllers, inner voltage and current loops, the virtual impedance loop, the voltage imbalance compensation. The proposed strategy balances the voltage of the single-phase critical loads by compensating the im...