Quantification of circulating endothelial cells by flow cytometry.

نویسندگان

  • Michiel H Strijbos
  • Jaco Kraan
  • Cor H J Lamers
  • Stefan Sleijfer
  • Jan W Gratama
چکیده

To the Editors: We read with great interest the article by Mancuso et al. (1) in the January edition of Clinical Cancer Research. In this article, the authors describe the validation of a novel multicolor flow cytometrical assay that allows the quantification of both circulating endothelial cells (CEC) and circulating endothelial progenitor cells (CEP), considered promising monitoring tools for vascular damage (vascular-derived CEC) or angiogenesis (bone marrow–derived CEP) in a large number of diseases with vascular involvement. Therefore, the development and validation of an assay by which these cells can be reliably detected are definitely warranted. Nevertheless, we feel that several issues deserve further attention. First, this article adds yet another reference value for CEC and CEP in healthy donors, namely 140 CEC/mL and 181 CEP/mL. These numbers are in sharp contrast to reference range CEC and CEP numbers reported in earlier studies from this group (mean, 7,900 CEC/mL and <500 CEP/mL, respectively; ref. 2), whereas the most recent article from this group reports on average 14,500 CEC/mL and 740 CEP/mL (3). Strikingly, all assays by Mancuso et al. (4, 5) largely exceed CEC numbers typically reported in literature, namely up to 20 CEC/mL. It is also remarkable that CEC counts greatly exceeded CEP counts in their initial study (2), whereas on the contrary, their current study reveals the opposite (1). In view of the large number of clinical studies that have been performed using the assay first published in Blood in 2001 (2) or modifications thereof (3), it is our opinion that the authors should elaborate on the discrepancy in CEC and CEP numbers between their assays, as well as on the effect this difference could have on the overall interpretation of the results. Second, the exact quantification of CEC and CEP is very confusing (1). Both EDTA and CPT tubes are drawn, but it is not indicated which tube is used for absolute counting and how these counts were obtained. The gold standard for obtaining absolute cell counts in flow cytometry is by using fluorescent counting beads, but use of these beads is not reported in theMaterials and Methods section (1). Furthermore, counting cells with a prevalence as low as CEC and CEP requires a large volume of blood, typically 1 to 4 mL, to assure a low coefficient of variation. Mancuso et al. (1) do not state the volume used; however, it is mentioned that at least 1 × 10 cells are acquired, which reportedly yielded 300 to 400 events, suggesting that CEC constitute 0.03% to 0.04% of nucleated cells. Based on these numbers, a normal blood sample, with a leukocyte count of 5 × 10/mL, would have 5 × 10 × 0.03% = 1,500 CEC, yet the authors report a mean CEC count of 140/mL. How would the authors explain this? Finally, we have some concerns about the validation by electron microscopy. Based on our own experience on this approach, we know that to obtain a cell pellet suitable for electron microscopy analysis, at least 800,000 cells are required to have a cell pellet large enough for preparing pellet sections. Given the reported mean CEC counts (140/mL) and recovery (average of 39%) after Ficoll, the authors would have needed 800,000/(140 × 0.39)/1,000 = 14.7 liters of blood to obtain enough cells for such a pellet. Even in the theoretical case of maximum CEC isolation, i.e., 100% recovery after Ficoll, 5.7 liters would be necessary. This issue needs clarification. Up to now, several assays enabling the detection of CEC and CEP have been described and others are likely to be published in the near future. In addition to establishing the true value of CEC and CEP enumeration in cancer and other diseases, general consensus on the best way to enumerate these cells is now definitely required.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Receptor for advanced glycation end products involved in circulating endothelial cells release from human coronary endothelial cells induced by C-reactive protein

Objective(s): This study was designed to investigate the effect of receptor for advanced glycation end products (RAGE), S100A12 and C-reactive protein (CRP) on the release of circulating endothelial cells (CECs) from human coronary artery endothelial cells (HCAECs). Materials and Methods: HCAECs were cultured in increasing concentration of CRP (0, 12.5, 25, 50μg/ml) or S100A12 protein (0, 4, 1...

متن کامل

Comparison of Two Flow Cytometric Methods for Detection of Human Invariant Natural Killer T Cells (iNKT)

Background: Invariant natural killer cells (iNKT) are an important immunoregulatory T cell subset. Currently several flow cytometry-based approaches exist for the identifi-cation of iNKT cells, which rely on using the 6B11 monoclonal antibody or a combina-tion of anti-Vα24 and anti-Vβ11 antibodies. Objective: The aim of this study was to compare the ability of two flow cytometry-based methods f...

متن کامل

Effect of Scurrula atropurpurea on nitric oxide, endothelial damage, and endothelial progenitor cells of DOCA-salt hypertensive rats

Objective(s):To know whether Scurrula atropurpurea is able to modulate total plasma nitrate/nitrite levels, decrease endothelial damage, and increase endothelial progenitor cells (EPCs) in hypertensive rats. Materials and Methods: The rats were divided in 5 groups: control (normotensive) group, Desoxy cortico sterone (DOCA)-salt hypertensive group, and three DOCA-salt hypertensive groups. All 5...

متن کامل

Evaluation of Flow Cytometry and Kleihauer Techniques for Quantification of Fetomaternal Hemorrhage: A Prospective Cohort Study in Southwestern Iran

Background: Quantification of fetal red blood cells (RBCs) in maternal blood is of great importance to calculate appropriate dose of post-deliver anti D immunoglobulin in a rhesus D (RhD)-negative woman. Objective: The aim of this study is to evaluate a direct immunofluorescence flow cytometry technique in artificial and clinical samples and compared it t...

متن کامل

Circulating endothelial cells in coronary artery disease.

BACKGROUND endothelial damage and dysfunction play a crucial role in the pathophysiology of coronary artery disease (CAD). The quantification of circulating endothelial cells (CEC) in the peripheral blood is a novel method for assessing endothelial damage. AIM to evaluate the possible diagnostic use of single quantification of CEC in peripheral blood by flow cytometry in patients with CAD. ...

متن کامل

Flow cytometric evaluation of circulating endothelial cells: a new protocol for identifying endothelial cells at several stages of differentiation.

Several factors may influence the analysis of endothelial cells (ECs) by flow cytometry: separation of mononuclear cell, washing and centrifugation steps, panel of monoclonal antibodies, and the lack of standardization of gating technique. Therefore, the reliable quantification of ECs remains a technical challenge. The purpose of this study is to define a new flow cytometric protocol to charact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical cancer research : an official journal of the American Association for Cancer Research

دوره 15 10  شماره 

صفحات  -

تاریخ انتشار 2009