4. Validation of the CrIS Fast Physical NH3 Retrieval with ground-based FTIR

ثبت نشده
چکیده

Presented here is the validation of the CrIS Fast Physical Retrieval (CFPR) NH3 column and profile measurements using ground-based Fourier Transform Infrared (FTIR) observations. We use the total columns and profiles from seven FTIR sites in the Network for the Detection of Atmospheric Composition Change (NDACC) to validate the satellite data products. The overall FTIR and CrIS total columns have a positive correlation of r = 0.77 (N=218) with very little bias (a slope of 1.02). Binning the comparisons by total column amounts, for concentrations larger than 10.0 x 1015 molecules cm-2, i.e. ranging from moderate to polluted conditions, the relative difference is on average ~ 0 5% with a standard deviation of 25-50%, which is comparable to the estimated retrieval uncertainties in both CrIS and the FTIR. For the smallest total column range (<10.0x1015 molecules cm-2) where there are a large number of observations at or near the CrIS noise level (detection limit) the absolute differences between CrIS and the FTIR total columns show a slight positive column bias. The CrIS and FTIR profile comparisons differences are mostly within the range of the estimated retrieval uncertainties single level retrieved profile values, showing average differences in the range of ~20 to 40%. The CrIS retrievals typically show good vertical sensitivity down into the boundary layer that typically peaks at ~850 hPa (~1.5 km), at this level the median absolute difference is 0.87 (std = ±0.08) ppb, corresponding to a median relative difference of 39% (std = ±2%). Most of the absolute and relative profile comparison differences are in the range of the estimated retrieval uncertainties. At the surface, where CrIS typically has lower sensitivity, it tends to overestimate under low concentrations conditions, and underestimate under higher atmospheric concentration conditions. Published as: Dammers, E., Shephard, M. W., Palm, M., Cady-Pereira, K., Capps, S., Lutsch, E., Strong, K., Hannigan, J. W., Ortega, I., Toon, G. C., Stremme, W., Grutter, M., Jones, N., Smale, D., Siemons, J., Hrpcek, K., Tremblay, D., Schaap, M., Notholt, J., and Erisman, J. W.: Validation of the CrIS Fast Physical NH3 Retrieval with ground-based FTIR, Atmospheric Measurement Techniques Discussions, doi:10.5194/amt-2017-38, in review, 2017.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interactive comment on “An evaluation of IASI-NH3 with ground-based FTIR measurements” by E. Dammers et al

The manuscript by Dammers et al. describes the result of comparisons between ground-based solar absorption FTIR and space-borne mid-infrared nadir observations of NH3 total column amounts. Due to its importance reaching from air-quality to climate change issues, high-quality measurements of ammonia with global coverage are significant contributions for our understanding of relevant processes an...

متن کامل

Interactive comment on “An evaluation of IASI-NH3 with ground-based FTIR measurements” by E. Dammers et al

1) Section 2.3.1: This section talks about the important spatial and temporal differences between the FTIR and IASI, which is very well done. However, due to the IASI retrieval approach the sometimes equally important vertical sampling difference are not taken into consideration. One sentence should be added stating that this difference cannot be determined due to the IASI retrieval and is thus...

متن کامل

First ground-based FTIR observations of methane in the inner tropics over several years

Total column concentrations of methane have been retrieved from ground-based solar absorption FTIR spectra in the near-infrared recorded in Paramaribo (Suriname). The methane FTIR observations are compared with TM5 model simulations and satellite observations from SCIAMACHY, and represent the first validation of SCIAMACHY retrievals in the inner tropics using ground-based remote sensing techniq...

متن کامل

Water vapour profiles by ground-based FTIR spectroscopy

Water vapour profiles by ground-based FTIR spectroscopy: study for an optimised retrieval and its validation M. Schneider, F. Hase, and T. Blumenstock IMK-ASF, Forschungszentrum Karlsruhe and Universität Karlsruhe, Germany Received: 7 July 2005 – Accepted: 31 August 2005 – Published: 29 September 2005 Correspondence to: M. Schneider ([email protected]) © 2005 Author(s). This work is...

متن کامل

Water vapour profiles by ground-based FTIR spectroscopy: study for an optimised retrieval and its validation

The sensitivity of ground-based instruments measuring in the infrared with respect to tropospheric water vapour content is generally limited to the lower and middle troposphere. The large vertical gradients and variabilities avoid a better sensitivity for the upper troposphere/lower stratosphere (UT/LS) region. In this work an optimised retrieval is presented and it is demonstrated that compare...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017