NIRS measurement of O(2) dynamics in contracting blood and buffer perfused hindlimb muscle.
نویسندگان
چکیده
In order to obtain evidence that Mb releases O(2) during muscle contraction, we have set up a buffer-perfused hindlimb rat model and applied NIRS to detect the dynamics of tissue deoxygenation during contraction. The NIRS signal was monitored on hindlimb muscle during twitch contractions at 1 Hz, evoked via electrostimulator at different submaximal levels. The hindlimb perfusion was carried out by perfusion of Krebs Bicarbonate buffer. The NIRS still detected a strong signal even under Hb-free contractions. The deoxygenation signal (Delta[deoxy]) was progressively increased at onset of the contraction and reached the plateau under both blood- and buffer-perfused conditions. However, the amplitude of Delta[deoxy] during steady state continued to significantly increase as tension increased. The tension-matched comparison of the Delta[deoxy] level under buffer-perfused and blood perfused conditions indicate that Mb can contribute approximately 50% to the NIRS signal. These results clarify the Mb contribution to the NIRS signal and show a falling intracellular PO(2) as workload increases.
منابع مشابه
The effect of vasoconstrictors on oxygen consumption in resting and contracting skeletal muscle of the autologous pump-perfused rat hindlimb.
This study used a novel in vivo model to test the hypothesis that nutritive and non-nutritive blood flow distribution can still be observed under conditions of high vascular tone and oxygen delivery at rest and in metabolically active (twitch contracting) skeletal muscle. Experiments were performed in a constant flow autologous pump-perfused hindlimb in anaesthetised male Wistar rats. Agonists ...
متن کاملPerformance of near-infrared spectroscopy in measuring local O(2) consumption and blood flow in skeletal muscle.
The aim of this study was to investigate local muscle O(2) consumption (muscV(O(2))) and forearm blood flow (FBF) in resting and exercising muscle by use of near-infrared spectroscopy (NIRS) and to compare the results with the global muscV(O(2)) and FBF derived from the well-established Fick method and plethysmography. muscV(O(2)) was derived from 1) NIRS using venous occlusion, 2) NIRS using a...
متن کاملAerobic power declines with aging in rat skeletal muscles perfused at matched convective O2 delivery.
Although it is well established that maximal O(2) uptake (Vo(2 max)) declines from adulthood to old age, the role played by alterations in skeletal muscle is unclear. Specifically, because during whole body exercise reductions in convective O(2) delivery to the working muscles from adulthood to old age compromise aerobic performance, this obscures the influence of alterations within the skeleta...
متن کاملModeling oxygenation in venous blood and skeletal muscle in response to exercise using near-infrared spectroscopy.
Noninvasive, continuous measurements in vivo are commonly used to make inferences about mechanisms controlling internal and external respiration during exercise. In particular, the dynamic response of muscle oxygenation (Sm(O(2))) measured by near-infrared spectroscopy (NIRS) is assumed to be correlated to that of venous oxygen saturation (Sv(O(2))) measured invasively. However, there are situa...
متن کاملPerfused rat hindlimb is suitable for skeletal muscle glucose transport measurements.
It has been postulated that the perfused rat hindlimb is unsuitable for measurements of muscle glucose transport [P. Hansen, E. Gulve, J. Gao, J. Schluter, M. Mueckler, and J. Holloszy. Am. J. Physiol. 268 ( Cell Physiol. 37): C30-C35, 1995]. The aim of the present study was therefore to critically evaluate the suitability of this preparation for glucose transport measurements using the extrace...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Advances in experimental medicine and biology
دوره 662 شماره
صفحات -
تاریخ انتشار 2010