Continuous glucose monitoring considerations for the development of a closed-loop artificial pancreas system.
نویسندگان
چکیده
BACKGROUND Commercialization of a closed-loop artificial pancreas system that employs continuous subcutaneous insulin infusion and interstitial fluid glucose sensing has been encumbered by state-of-the-art technology. Continuous glucose monitoring (CGM) devices with improved accuracy could significantly advance development efforts. However, the current accuracy of CGM devices might be adequate for closed-loop control. METHODS The influence that known CGM limitations have on closed-loop control was investigated by integrating sources of sensor inaccuracy with the University of Virginia Padova Diabetes simulator. Non-glucose interference, physiological time lag and sensor error measurements, selected from 83 Enlite™ glucose sensor recordings with the Guardian® REAL-Time system, were used to modulate simulated plasma glucose signals. The effect of sensor accuracy on closed-loop controller performance was evaluated in silico, and contrasted with closed-loop clinical studies during the nocturnal control period. RESULTS Based on n = 2472 reference points, a mean sensor error of 14% with physiological time lags of 3.28 ± 4.62 min (max 13.2 min) was calculated for simulation. Sensor bias reduced time in target for both simulation and clinical experiments. In simulation, additive error increased time <70 mg/dl and >180 mg/dl by 0.2% and 5.6%, respectively. In-clinic, the greatest low blood glucose index values (max = 5.9) corresponded to sensor performance. CONCLUSION Sensors have sufficient accuracy for closed-loop control, however, algorithms are necessary to effectively calibrate and detect erroneous calibrations and failing sensors. Clinical closed-loop data suggest that control with a higher target of 140 mg/dl during the nocturnal period could significantly reduce the risk for hypoglycemia.
منابع مشابه
Continuous Performance Monitoring of a Closed-Loop Insulin Delivery System using Bayesian Surprise
The development of an artificial pancreas for the treatment of insulin-dependent diabetes is a big challenge for control theory. Many closed-loop algorithms have been widely evaluated for their ability to recreate, as closely as possible, glucose and insulin profiles observed in healthy individuals. Nevertheless, an artificial pancreas system also involves a critical necessity for supervision o...
متن کاملGlucose sensing issues for the artificial pancreas.
The first retrospective continuous glucose monitor entered the market in 1999. Now that this tool gives online data, the question arises whether it is ready to be incorporated into a closed-loop system. The author discusses the following questions: (1) Is the accuracy of current continuous glucose monitoring (CGM) systems good enough for use in a prototype artificial pancreas system?; (2) How d...
متن کاملOptimal Model Based Control for Blood Glucose Insulin System Using Continuous Glucose Monitoring
The level of glucose control in the human body is very important, because increase in glucose level in diabetic patients for long time causes blindness and cardiovascular problem. In this paper, closed loop insulin system for diabetic patients is proposed to regulate the blood glucose level. Hence, continuous monitoring and control of glucose level is necessary for Type 1 diabetes patients. In ...
متن کاملHypoglycemia Prevention in Closed-Loop Artificial Pancreas for Patients with Type 1 Diabetes
The current chapter addresses the problem of hypoglycemia in type 1 diabetes from biomedical and control engineering points of view. It gives a general introduction to the artificial pancreas system, and the risk of hypoglycemia in closed-loop insulin treatment. Then, it provides a review on the state of the art in hypoglycemia control, and the recent approaches in dealing with hypoglycemia in ...
متن کاملThe artificial pancreas: current status and future prospects in the management of diabetes.
Recent advances in insulins, insulin pumps, continuous glucose-monitoring systems, and control algorithms have resulted in an acceleration of progress in the development of artificial pancreas devices. This review discusses progress in the development of external systems that are based on subcutaneous drug delivery and subcutaneous continuous glucose monitoring. There are two major system-level...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of diabetes science and technology
دوره 5 6 شماره
صفحات -
تاریخ انتشار 2011