Two immunofluorescent methods compared with a radial immunodiffusion method for measurement of serum immunoglobulins.

نویسندگان

  • G C Blanchard
  • R Gardner
چکیده

We found high correlations when the values for immunoglobulins G, A, and M, obtained from the analysis of a group of 50 or more human sera by a measured-time radial immunodiffusion method, were compared to values found by two new commercial immunofluorescent methods. The Fiax and the Immuno-Fluor systems make use of fluorescently labeled antibodies and solid-phase immunoadsorbents and offer simple, precise, and objective methods for immunoglobulin quantitation. The Fiax procedure is less time consuming than is the Immuno-Fluor and gives IgG and IgA concentrations that are in close agreement with those found by radial immunodiffusion and IgM values that are significantly lower than the radial immunodiffusion values. The IgG results determined by the Immuno-Fluor method compare well with the radial immunodiffusion results, uhile the IgA values are significantly higher and IgM values significantly lower than those obtained by radial immunodiffusion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser nephelometric measurement of seven serum proteins compared with radial immunodiffusion.

Quantification of immunoglobulins IgG, IgA, IgM, C3 complement, siderophilin, alpha 2-macroglobulin and haptoglobin in serum by a Behring laser nephelometer coupled with a date processing apparatus was compared with values obtained by the radial immunodiffusion method of Mancini. The precision was not improved by the use of the laser nephelometer as compared to Mancini radial immunodiffusion, b...

متن کامل

Comparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.

After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...

متن کامل

Manual NephelometricMethodsfor Immunochemical

Manual procedures are presented for determining immunoglobulins IgG, IgA, and 1gM in human serum. The three immunoglobulins are quantitated, after reaction with specific ant sera, by measuring light scattering by the antigen-antibody complexes. The procedure is standardized by use of pooled human serum with known concentrations of IgG, IgA, and 1gM. Results with the present system correlated ex...

متن کامل

Rapid quantitation of serum immunoglobulins with a miniature centrifugal analyzer.

For these quantitative turbidimetric assays for immunoglobulins IgG, IgA, and IgM in serum, the reagents used are commercially available in kit form. The two-point assays are performed with a miniature centrifugal analyzer (GEMENI, Electro-Nucleonics, Inc.). The reading taken 5 s after mixing is used to correct for specimen turbidity. Run-to-run precision (CV) was typically 5% (range: 3.0-8.7%)...

متن کامل

An automated bichromatic measurement of serum immunoglobulins.

A new, rapid, discrete sampling and automated bichromatic procedure for the measurement of various soluble antigen-antibody complexes of immunoglobulins is described. The incorporation of polymeric substances and salts into the reaction mixture has greatly increased the sensitivity, shortened the reaction time and decreased the cost of the tests. Statistical analyses of data from this method ha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 1978