Plethysmographic variability index (PVI) accuracy in predicting fluid responsiveness in anesthetized children.
نویسندگان
چکیده
INTRODUCTION Plethysmographic Variability Index (PVI) has been shown to accurately predict responsiveness to fluid loads in adults. The goal of this study was to evaluate PVI accuracy when predicting fluid responsiveness during noncardiac surgery in children. MATERIAL AND METHODS Children aged 2-10 years scheduled for noncardiac surgery under general anesthesia were included. PVI was assessed concomitantly with stroke volume index (SVI). A response to fluid load was defined by an SVI increase of more than 15%. A 10 ml·kg(-1) normal saline intravenous fluid challenge was administered before surgical incision and after anesthetic induction. After incision, fluid challenges were administered when SVI values decreased by more than 15% or where judged necessary by the anesthesiologist. Statistical analyses include receiving operator characteristics (ROC) analysis and the determination of gray zone method with an error tolerance of 10%. RESULTS Fifty-four patients were included, 97 fluid challenges administered and 45 responses recorded. Area under the curve of ROC curves was 0.85 [0.77-0.93] and 0.8 [0.7-0.89] for baseline PVI and SVI values, respectively. Corresponding gray zone limits were [10-17%] and [22-31 ml·m(-2)], respectively. PVI values exhibited different gray zone limits for pre-incision and postincision fluid challenges, whereas SVI values were comparable. PVI value percentages in the gray zone were 34% overall and 44% for challenges performed after surgical incision. DISCUSSION This study found both PVI and prechallenge SVI to be accurate when used to predict fluid load response during anesthetized noncardiac surgery in children. However, a third of recorded PVI values were inconclusive.
منابع مشابه
Clinical investigation of plethysmographic variability index: A derivative index of pulse oximetry in anesthetized dogs
Paranjape, Vaidehi V. M.S., Purdue University, August 2014. Clinical Investigation of Plethysmographic Variability Index: A Derivative Index of Pulse Oximetry in Anesthetized Dogs. Major Professor: Jeff C. Ko. Plethysmographic Variability Index (PVI) is a derivative index of pulse oximetry that allows evaluating an individual's intravascular volume status. Perfusion Index (PI) represents the st...
متن کاملInfluence of the site of measurement on the ability of plethysmographic variability index to predict fluid responsiveness.
BACKGROUND Plethysmographic variability index (PVI) is an accurate predictor of fluid responsiveness in mechanically ventilated patients. However, the site of measurement of the plethysmographic waveform impacts its morphology and its respiratory variation. The goal of this study was to investigate the ability of PVI to predict fluid responsiveness at three sites of measurement (the forehead, e...
متن کاملPleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine.
BACKGROUND In patients receiving an infusion of norepinephrine, the relationship between the amplitude of the oximeter plethysmographic waveform and stroke volume may be variable and quality of the waveform might be reduced, compared with patients not receiving norepinephrine. We assessed the reliability of the pleth variability index (PVI), an automatic measurement of the respiratory variation...
متن کاملPredicting stroke volume and arterial pressure fluid responsiveness in liver cirrhosis patients using dynamic preload variables: A prospective study of diagnostic accuracy.
BACKGROUND Predicting whether a fluid challenge will elicit 'fluid responsiveness' in stroke volume (SV) and arterial pressure is crucial for managing hypovolaemia and hypotension. Pulse pressure variation (PPV), SV variation (SVV) and the plethysmographic variability index (PVI) have been shown to predict SV fluid responsiveness, and the PPV/SVV ratio has been shown to predict arterial pressur...
متن کاملPleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.
BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanicall...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Paediatric anaesthesia
دوره 23 6 شماره
صفحات -
تاریخ انتشار 2013