Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
نویسندگان
چکیده
BACKGROUND Noninvasive blood pressure (BP) measurement is essential for the study of human physiology but automatic oscillometric devices only estimate SBP and DBP using various, undisclosed algorithms, precluding standardization and interchangeability. We propose a novel approach by tracking, during pneumatic cuff deflation, the time interval from the foot to the apex of the systolic peak of the oscillometric signal, which reaches a maximum concomitant with the first Korotkoff sound. METHOD In 145 study participants and patients (group 1), we measured the systolic brachial artery blood pressure by Korotkoff sound recording, conventional oscillometry, and our fully automated systolic peak foot-to-apex time interval (SFATI) technique. In 35 other patients (group 2), we compared SFATI with intra-arterial measurement. RESULTS In group 1, the concordance correlation coefficient was 0.989 and 0.984 between SFATI and Korotkoff sounds, 0.884 and 0.917 between oscillometry and Korotkoff sounds, and 0.882 and 0.919 between SFATI and oscillometry, respectively, on the left and right arm. In group 2, it was 0.72 between SFATI and intra-arterial measurement, 0.67 between oscillometry and intra-arterial measurement, and 0.92 between SFATI and Korotkoff sounds. In 40 study participants, the reproducibility study yielded a concordance coefficient of 0.95 for SFATI and 0.94 for Korotkoff sounds. CONCLUSION SFATI BP measurement shows an excellent concordance with the auscultatory technique, offering a major improvement over current oscillometric techniques and allowing standardization.
منابع مشابه
Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits
BACKGROUND Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the ...
متن کامل2013 IEEE MeMeA Proceedings
Non-invasive measurement of the human blood pressure remains, although the commercial availability of such monitors, an active research topic. This is due to the disadvantage that the blood pressure is computed instead of directly measured. To compute the systolic and diastolic blood pressures from the oscillometry, the envelope of the oscillometric waveform is used to retrieve the systolic and...
متن کاملتأثیر وضعیتهای مختلف قرارگیری اندامهای بیماران مبتلا به پرفشاری خون بر میزان فشارخون آنان
Introduction: In hypertensive patients M position (sitting, right arm at the level of heart and both plantar surface of foots on the floor) is the standard position for measurment of blood pressure since it reveals the “true” pressure. Materials and Methods: It is a quaziexperimental study that compares effect of different positions of limbs on blood pressure of hypertensive patients. The sampl...
متن کاملBias and variability in blood pressure measurement with ambulatory recorders.
This study sought to determine whether patient characteristics such as age, sex, blood pressure, and pulse pressure differently affect the accuracy of an oscillometric (SpaceLabs 90207) and a microphonic (TM2420 version 7) blood pressure monitor. Blood pressure recorded by two oscillometric and two microphonic ambulatory monitors was compared with simultaneous readings by two pairs of trained, ...
متن کاملEstimated confidence interval from single blood pressure measurement based on algorithmic fusion
BACKGROUND Current oscillometric blood pressure measurement devices generally provide only single-point estimates for systolic and diastolic blood pressures and rarely provide confidence ranges for these estimates. A novel methodology to obtain confidence intervals (CIs) for systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimates from a single oscillometric blood pressure mea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 35 شماره
صفحات -