Non-Linearity Corrections and Statistical Uncertainties Associated with Near-Infrared Arrays
نویسندگان
چکیده
We derive general equations for non-linearity corrections and statistical uncertainty (variance) estimates for data acquired with near-infrared detectors employing correlated double sampling, multiple correlated double sampling (Fowler sampling) and uniformly-spaced continuous readout techniques. We compare our equation for the variance on each pixel associated with Fowler sampling with measurements obtained from data taken with the array installed in the nearinfrared cross-dispersed spectrograph (SpeX) at the NASA Infrared Telescope Facility and find that it provides an accurate representation of the empirical results. This comparison also reveals that the read noise associated with a single readout of the SpeX array increases with the number of non-destructive reads, nr, as n 0.16 r . This implies that the effective read noise of a stored image decreases as n r , shallower than the expected rate of n −0.5 r . The cause of this read noise behavior is uncertain, but may be due to heating of the array as a result of the multiple read outs. Such behavior may be generic to arrays that employ correlated or multiple correlated double sampling readouts. Subject headings: instrumentation: detectors — methods: data analysis
منابع مشابه
Multivariate calibration of near infrared spectroscopy in the presence of light scattering effect: a comparative study
When analyzing heterogeneous samples using spectroscopy, the light scattering effect introduces non-linearity into the measurements and deteriorates the prediction accuracy of conventional linear models. This paper compares the prediction performance of two categories of chemometric methods: pre-processing techniques to remove the non-linearity, and non-linear calibration techniques to directly...
متن کاملNear-infrared spectroscopy of H3+ above the barrier to linearity.
Since the Royal Society Discussion Meeting on H3+ in 2000, the laboratory spectroscopy of H3+ has entered a new regime. For the first time, transitions of H3+ above the barrier to linearity have been observed. A highly sensitive near-infrared spectrometer based on a titanium:sapphire laser and incorporating a dual-beam, double-modulation technique with bidirectional optical multi-passing has be...
متن کاملMonte Carlo investigation on precise dosimetry of HDR breast brachytherapy with Accuboost
Introduction: Accuboost is a HDR brachytherapy system in early stages breast cancer treatment. This device provides a completely noninvasive procedure with parallel-opposed radiation from two immobilizing peripheral applicators that caused it a preferred option of modalities to choose. In most commercial treatment planning systems, tissues are considered as a simple water phan...
متن کاملDesign of A Hyperspectral Nitrogen Sensing System for Citrus
Abstract. Citrus is one of the most important agricultural crop in Florida. Heavy reliance on agricultural chemicals and low fertilizer efficiencies have raised environmental and economic concerns. In this study, a system to sense nitrogen levels in a single citrus leaf was developed. Based on chlorophyll and protein spectral absorption bands, the sensing system’s wavelength ranges were chosen ...
متن کاملTop quark mass determination near tt̄ threshold at lepton colliders ∗
Top quark mass determination near t ¯ t threshold at lepton colliders * Abstract Future e + e − linear colliders will enable us to determine the top quark mass with high accuracy from the measurement of the 1S peak position of (remnant of) toponium. The estimated statistical error in this measurement is about 50 MeV with integrated luminosity of 30 fb −1. We calculate O(α 5 s m) corrections to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004