Clinical evaluation of the Sorin Synthesis oxygenator with integrated arterial filter.
نویسندگان
چکیده
The use of arterial line filters has long been a standard of practice in the field of cardiopulmonary bypass. Sorin Biomedica has designed an adult hollow-fiber oxygenator that not only incorporates their Mimesys biomimicry coating technology but also has a 40-micron arterial filter as an integrated component of this unique membrane oxygenator. We did a prospective, randomized clinical trial of 54 Synthesis coated oxygenators and compared them with 54 uncoated Monolyth Pro oxygenators, the latter of which incorporated an external arterial line filter with a standard bypass loop There were few statistically significant differences found between the Synthesis group and the Monolyth group with regard to pressure differentials, hemodynamic resistance, and platelet drop. The Synthesis oxygenator did require less priming volume, but the amount was not significant. Platelet counts with the Phosphorylcholine coated Synthesis oxygenators, using crystalloid perfusates, was similar to our previously published data on platelet protection and Albumin perfusates. We conclude that the Sorin Synthesis oxygenator appears to have better flow characteristics than the Monolyth oxygenator, with the potential for lower priming volumes. The most clinically significant benefit comes from the elimination of the arterial filter bypass loop and the avoidance of inverting the arterial filter during priming.
منابع مشابه
Oxygenator safety evaluation: a focus on connection grip strength and arterial temperature measurement accuracy.
This report describes the assessment of three specific safety-related specifications in the consideration of an alternate oxygenator; first the grip strength relationship between various oxygenator connectors and SMARxT tubing, second, the grip strength of various biopassive tubings and an isolated SMARxT connector, and finally, the accuracy of the arterial outlet temperature measurement. Grip ...
متن کاملEvaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.
Gaseous microemboli (GME) remain a challenge for cardiopulmonary bypass procedures in adult as well as pediatric cardiac surgery patients. The present study tested the effectiveness of a new adult membrane oxygenator in models both with and without an integrated arterial filter to evaluate GME trapping capability and determine membrane pressure drops at various flow rates and temperatures. The ...
متن کاملIn vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.
The delivery of gaseous microemboli (GME) by the cardiopulmonary bypass circuit should be minimized whenever possible. Innovations in components, such as the integration of arterial line filter (ALF) and ALFs with reduced priming volumes, have provided clinicians with circuit design options. However, before adopting these components clinically, their GME handling ability should be assessed. Thi...
متن کاملPost-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study.
During a previously published study on gaseous microemboli (GMEs) and perfusionist interventions, it was noted that emboli could be detected after the arterial filter when blood/air challenges entered the membrane oxygenator's integral cardiotomy. The findings indicated that further study into the oxygenator's integral cardiotomy reservoir was warranted. This is the first know published report ...
متن کاملAir Transmission Comparison of the Affinity Fusion Oxygenator with an Integrated Arterial Filter to the Affinity NT Oxygenator with a Separate Arterial Filter.
Arterial filters used in the extracorporeal circuit (ECC) have been shown to minimize cerebral injury by capturing particulate matter and microbubbles. We clinically use the Affinity NT oxygenator with an Affinity arterial filter attached ("Affinity system"). The new Affinity Fusion oxygenator ("Fusion") incorporates integrated arterial filtering. Our aim was to determine if the Fusion oxygenat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2005