Infrared mapping of ultrasound fields generated by medical transducers: feasibility of determining absolute intensity levels.

نویسندگان

  • Vera A Khokhlova
  • Svetlana M Shmeleva
  • Leonid R Gavrilov
  • Eleanor Martin
  • Neelaksh Sadhoo
  • Adam Shaw
چکیده

Considerable progress has been achieved in the use of infrared (IR) techniques for qualitative mapping of acoustic fields of high intensity focused ultrasound (HIFU) transducers. The authors have previously developed and demonstrated a method based on IR camera measurement of the temperature rise induced in an absorber less than 2 mm thick by ultrasonic bursts of less than 1 s duration. The goal of this paper was to make the method more quantitative and estimate the absolute intensity distributions by determining an overall calibration factor for the absorber and camera system. The implemented approach involved correlating the temperature rise measured in an absorber using an IR camera with the pressure distribution measured in water using a hydrophone. The measurements were conducted for two HIFU transducers and a flat physiotherapy transducer of 1 MHz frequency. Corresponding correction factors between the free field intensity and temperature were obtained and allowed the conversion of temperature images to intensity distributions. The system described here was able to map in good detail focused and unfocused ultrasound fields with sub-millimeter structure and with local time average intensity from below 0.1 W/cm(2) to at least 50 W/cm(2). Significantly higher intensities could be measured simply by reducing the duty cycle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of high intensity focused ultrasound transducers using acoustic streaming.

A new approach for characterizing high intensity focused ultrasound (HIFU) transducers is presented. The technique is based upon the acoustic streaming field generated by absorption of the HIFU beam in a liquid medium. The streaming field is quantified using digital particle image velocimetry, and a numerical algorithm is employed to compute the acoustic intensity field giving rise to the obser...

متن کامل

Free hydroxyl radical dosimetry by using 1 MHz low level ultrasound waves

  ABSTRACTBackground : In order to quantify effects of ultrasound irradiation parameters under therapeutic condition, especially sonodynamic therapy, it is initially necessary to evaluate inertial cavitation activity in vitro conditions therefore, in this study, the effect of 1 MHz low level ultrasound based on °OH radicals generated by acoustic inertial cavitation in aqueous solution was monit...

متن کامل

Simulation of hemispherical transducers for transcranial HIFU treatments using the hybrid angular spectrum approach

Background/introduction Transcranial focused ultrasound is emerging as a promising treatment modality for a variety of disorders including essential tremor and glioblastoma. However, traditional full-wave methods of simulating ultrasound pressure fields for these treatments, such as FDTD, are computationally intensive. The situation is exacerbated by the large area insonified by the transcrania...

متن کامل

Focused ultrasound transducer spatial peak intensity estimation: a comparison of methods.

Characterisation of the spatial peak intensity at the focus of high intensity focused ultrasound transducers is difficult because of the risk of damage to hydrophone sensors at the high focal pressures generated. Hill et al (1994 Ultrasound Med. Biol. 20 259-69) provided a simple equation for estimating spatial-peak intensity for solid spherical bowl transducers using measured acoustic power an...

متن کامل

Quantitative assessment of acoustic intensity in the focused ultrasound field using hydrophone and infrared imaging.

With the popularity of ultrasound therapy in clinics, characterization of the acoustic field is important not only to the tolerability and efficiency of ablation, but also for treatment planning. A quantitative method was introduced to assess the intensity distribution of a focused ultrasound beam using a hydrophone and an infrared camera with no prior knowledge of the acoustic and thermal para...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 134 2  شماره 

صفحات  -

تاریخ انتشار 2013