Comparative performance analysis of time-frequency distributions for spectroscopic optical coherence tomography.

نویسندگان

  • Chenyang Xu
  • Farzad Kamalabadi
  • Stephen A Boppart
چکیده

The analysis of spectroscopic optical coherence tomography (SOCT) signals suffers the trade-off between time resolution and frequency resolution. Various joint time-frequency distributions (TFDs) can optimize this trade-off. Synthesized signals were generated and experimentally acquired data were obtained to compare and validate several different TFDs under different SOCT imaging schemes. Specific criteria were designed to quantify the TFD performance. We found that different SOCT imaging schemes require different optimal TFDs. Cohen's class TFDs generate the most compact time-frequency (TF) analysis, while linear TFDs offer the most reliable TF analysis. In both cases, if some prior information is known, model-based TF analysis can improve the performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual window method for processing spectroscopic optical coherence tomography signals with simultaneously high spectral and temporal resolution.

Current methods for analysis of spectroscopic optical coherence tomography (SOCT) signals suffer from an inherent tradeoff between time (depth) and frequency (wavelength) resolution. Here, we present a dual window (DW) method for reconstructing time frequency distributions (TFDs) that applies two orthogonal Gaussian windows that independently determine the spectral and temporal resolution. The ...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...

متن کامل

Spectroscopic spectral-domain optical coherence microscopy.

The spectroscopic content within optical coherence tomography (OCT) data can provide a wealth of information. Spectroscopic OCT methods are frequently limited by time-frequency trade-offs that limit high spectral and spatial resolution simultaneously. We present spectroscopic spectral-domain optical coherence microscopy performed with a multimodality microscope. Restricting the spatial extent o...

متن کامل

Separation of absorption and scattering profiles in spectroscopic optical coherence tomography using a least-squares algorithm.

In spectroscopic optical coherence tomography, it is important and useful to separately estimate the absorption and the scattering properties of tissue. In this paper, we propose a least-squares fitting algorithm to separate absorption and scattering profiles when near-infrared absorbing dyes are used. The algorithm utilizes the broadband Ti:sapphire laser spectrum together with joint time-freq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 44 10  شماره 

صفحات  -

تاریخ انتشار 2005