Non-invasive Assessment of Transstenotic Pressure Gradients Utilizing 3D Phase Contrast MRA: Validation against Endovascular Pressure Measurements in a Porcine Study

نویسندگان

  • T. A. Bley
  • K. M. Johnson
  • O. Wieben
  • C. J. Francois
  • S. B. Reeder
  • M. L. Schiebler
  • D. P. Lum
  • T. M. Grist
چکیده

Fig. 2 Significant Renal Artery Stenosis Selective DSA demonstrates a significant renal artery stenosis (A, TSPG = 48mmHg. Streamlines discontinue at the stenosis indicating a significant luminal narrowing (B). Please note flow signal distal to the stenosis indicating high degree stenosis but excluding occlusion. Non-invasive Assessment of Transstenotic Pressure Gradients Utilizing 3D Phase Contrast MRA: Validation against Endovascular Pressure Measurements in a Porcine Study

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeatability and internal consistency of abdominal 2D and 4D PC MR flow measurements

Background We have recently demonstrated the benefits of a radially undersampled 4D-MR flow acquisition (PC-VIPR) [1,2] for angiographic imaging of the renal vasculature in humans [3] and for transstenotic pressure gradients in a swine model [4]. Validation of velocity measurements in vivo with non-MRI methods is desirable, but not possible. The purpose of this study was to assess the repeatabi...

متن کامل

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

Utilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease.

Aim of this study is the assessment of feasibility and clinical usefulness of a new index of stenosis severity, the slope of the instantaneous transstenotic pressure gradient/velocity relationship. Twenty-one patients scheduled for percutaneous revascularization procedures were studied with simultaneous measurement of poststenotic coronary pressure and flow velocity, in basal condition and duri...

متن کامل

Noninvasive measurement of intra-aneurysmal pressure and flow pattern using phase contrast with vastly undersampled isotropic projection imaging.

BACKGROUND AND PURPOSE Currently, more reliable parameters to predict the risk of aneurysmal rupture are needed. Intra-aneurysmal pressure gradients and flow maps could provide additional information regarding the risk of rupture. Our hypothesis was that phase contrast with vastly undersampled isotropic projection reconstruction (PC-VIPR), a novel 3D MR imaging sequence, could accurately assess...

متن کامل

Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: validation in an anatomically accurate cerebral artery aneurysm model with steady flow.

PURPOSE To verify the accuracy of velocity mapping with three-dimensional (3D) phase-contrast magnetic resonance angiography (PC-MRA) for steady flow in a realistic model of a cerebral artery aneurysm at a 3T scanner. MATERIALS AND METHODS Steady flow through an original geometry model of a cerebral aneurysm was mapped at characteristic positions by state-of-the-art laser Doppler velocimetry ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008