Application of the stretched exponential function to fluorescence lifetime imaging.

نویسندگان

  • K C Lee
  • J Siegel
  • S E Webb
  • S Lévêque-Fort
  • M J Cole
  • R Jones
  • K Dowling
  • M J Lever
  • P M French
چکیده

Conventional analyses of fluorescence lifetime measurements resolve the fluorescence decay profile in terms of discrete exponential components with distinct lifetimes. In complex, heterogeneous biological samples such as tissue, multi-exponential decay functions can appear to provide a better fit to fluorescence decay data than the assumption of a mono-exponential decay, but the assumption of multiple discrete components is essentially arbitrary and is often erroneous. Moreover, interactions, both between fluorophores and with their environment, can result in complex fluorescence decay profiles that represent a continuous distribution of lifetimes. Such continuous distributions have been reported for tryptophan, which is one of the main fluorophores in tissue. This situation is better represented by the stretched-exponential function (StrEF). In this work, we have applied, for the first time to our knowledge, the StrEF to time-domain whole-field fluorescence lifetime imaging (FLIM), yielding both excellent tissue contrast and goodness of fit using data from rat tissue. We note that for many biological samples for which there is no a priori knowledge of multiple discrete exponential fluorescence decay profiles, the StrEF is likely to provide a truer representation of the underlying fluorescence dynamics. Furthermore, fitting to a StrEF significantly decreases the required processing time, compared with a multi-exponential component fit and typically provides improved contrast and signal/noise in the resulting FLIM images. In addition, the stretched-exponential decay model can provide a direct measure of the heterogeneity of the sample, and the resulting heterogeneity map can reveal subtle tissue differences that other models fail to show.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of the stretched exponential function to fluorescence lifetime imaging of biological tissue

The fluorescence decay in fluorescence lifetime imaging (FLIM) is typically fitted to a multi-exponential model with discrete lifetimes. The interaction between fluorophores in heterogeneous samples (e.g. biological tissue) can, however, produce complex decay characteristics that do not correspond to such models. Although they appear to provide a better fit to fluorescence decay data than the a...

متن کامل

Concentration dependence of the fluorescence decay profile in transition metal doped chalcogenide glass

In this paper we present the fluorescence decay profiles of vanadium and titanium doped gallium lanthanum sulphide (GLS) glass at various doping concentrations between 0.01 and 1% (molar). We demonstrate that below a critical doping concentration the fluorescence decay profile can be fitted with the stretched exponential function: exp[-(t/τ)], where τ is the fluorescence lifetime and β is the s...

متن کامل

FLIMX: A Software Package to Determine and Analyze the Fluorescence Lifetime in Time-Resolved Fluorescence Data from the Human Eye

Fluorescence lifetime imaging ophthalmoscopy (FLIO) is a new technique for measuring the in vivo autofluorescence intensity decays generated by endogenous fluorophores in the ocular fundus. Here, we present a software package called FLIM eXplorer (FLIMX) for analyzing FLIO data. Specifically, we introduce a new adaptive binning approach as an optimal tradeoff between the spatial resolution and ...

متن کامل

Studying biological tissue with fluorescence lifetime imaging: microscopy, endoscopy, and complex decay profiles.

We have applied fluorescence lifetime imaging (FLIM) to the autofluorescence of different kinds of biological tissue in vitro, including animal tissue sections and knee joints as well as human teeth, obtaining two-dimensional maps with functional contrast. We find that fluorescence decay profiles of biological tissue are well described by the stretched exponential function (StrEF), which can re...

متن کامل

Total variation versus wavelet-based methods for image denoising in fluorescence lifetime imaging microscopy.

We report the first application of wavelet-based denoising (noise removal) methods to time-domain box-car fluorescence lifetime imaging microscopy (FLIM) images and compare the results to novel total variation (TV) denoising methods. Methods were tested first on artificial images and then applied to low-light live-cell images. Relative to undenoised images, TV methods could improve lifetime pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biophysical journal

دوره 81 3  شماره 

صفحات  -

تاریخ انتشار 2001