Intercomparison of dosimetry systems based on CaF2:Mn TL detectors.
نویسندگان
چکیده
The responses of readings by the TL dosimetry system MR200 TL developed in-house and used at JSI and the TOLEDO TL system used at RBI are compared. Ten measurements at different doses ranging from 0.01 mSv to 5 Sv were carried out. A set of 36 dosemeters with three pellets of CaF2:Mn were irradiated in radiation fields of 137Cs and 60Co. Analysis of the measured results shows that at doses below 0.1 Sv, readers' outputs do not differ >5% from each other. At doses >1 Sv, the results obtained by the MR200 reader must be corrected with a known factor. Finally, the reproducibility of the results from the MR200 was tested.
منابع مشابه
Recovery of thermoluminescence sensitivity in CaF2:Mn (TLD-400) dosimeter under heating process
In order to recovery the thermoluminescence (TL) sensitivity of CaF2:Mn (TLD-400) thermoluminescent dosimeter it was exposed to high gamma radiation dose of 10kGy, then by applying standard annealing followed by irradiation to 1Gy gamma dose, the TL signal was recorded . The TL response reduced due to the damage effect of high dose irradiation in comparison with control dosimeter with received ...
متن کاملInfluence of environmental changes on integrating radon detectors: results of an intercomparison exercise.
An intercomparison exercise for passive integrating radon detectors has been carried out with the participation of 12 detection systems from 10 laboratories. The detection systems comprise three commonly used in radon integrating measurements, tracks, activated charcoal canisters and electrets. The exposures were carried out in the radon and thoron chambers at the Institute of Energy Techniques...
متن کاملApplicability of Thermoluminescent Dosimeters in X-ray Organ Dose Determination and in the Dosimetry of Systemic and Boron Neutron Capture Radiotherapy
The main detectors used for clinical dosimetry are ionisation chambers and semiconductors. Thermoluminescent (TL) dosimeters are also of interest because of their following advantages: i) wide useful dose range, ii) small physical size, iii) no need for high voltage or cables, i.e. stand alone character, and iv) tissue equivalence (LiF) for most radiation types. TL detectors can particularly be...
متن کاملA Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region
Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...
متن کاملAnalytical Study of Phosphors for Radiation Dosimetry
169 ANALYTICAL STUDY OF PHOSPHORS FOR RADIATION DOSIMETRY Pankaj Pathak1,Manisha Singh2, Pankaj Kumar Mishra3 1,2,3Department of Applied Physics, Amity School of Engineering & Technology, Amity University, Gwalior (MP) Email:[email protected] Abstract The main aim of the study is to analyse the different luminescence properties of phosphors synthesised by Combustion Synthesis (CS) Techniq...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiation protection dosimetry
دوره 119 1-4 شماره
صفحات -
تاریخ انتشار 2006