Externalized conductors and insulation failure in Biotronik defibrillator leads: History repeating or a false alarm?

نویسندگان

  • Elia De Maria
  • Ambra Borghi
  • Lorenzo Bonetti
  • Pier Luigi Fontana
  • Stefano Cappelli
چکیده

Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation ("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee.

BACKGROUND The Riata family of implantable cardioverter-defibrillator (ICD) leads is prone to a specific insulation abrasion characterized by externalization of conductor cables. The objective of this study was to determine the prevalence of externalized conductors and electrical abnormalities in Riata ICD leads by fluoroscopic screening and standard ICD interrogation. METHODS AND RESULTS All...

متن کامل

Repetitive inappropriate implantable cardioverter-defibrillator shocks due to insulation failure with externalized conductor cables of a Biotronik Linox SD ICD lead.

We report the case of a 54-year-old patient with repetitive inappropriate implantable cardioverter-defibrillator (ICD) shocks due to externalized pace-sense conductor cables of a Biotronik Linox SD 65/16 ICD lead. This case report is one of few in the literature describing inappropriate shocks due to insulation failure with externalization of conductor cables of an ICD lead from the Biotronik L...

متن کامل

Fluoroscopic investigation of Riata® transvenous defibrillator leads.

BACKGROUND Implantable cardioverter-defibrillator leads from Riata® family (St. Jude Medical Inc., Sylmar, CA, USA) have been recently recalled by Food and Drug Administration for concerns of a unique type of "inside-out" insulation failure leading to conductor externalization. The objective of this study was to evaluate the prevalence and predictors of conductor externalization in patients imp...

متن کامل

A Comparative Study of Defibrillator Leads at a Large-Volume Implanting Hospital: Results From the Pacemaker and Implantable Defibrillator Leads Survival Study ("PAIDLESS").

OBJECTIVES The purpose of the study was to examine survival in the implantable defibrillator subset of implanted leads at a large-volume implanting hospital. BACKGROUND Implantable lead survival has been the subject of many multicenter studies over the past decade. Fewer large implanting volume single-hospital studies have examined defibrillator lead failure as it relates to patient survival ...

متن کامل

Canadian Registry of Implantable Electronic Device Outcomes

An advisory related to the Riata and Riata ST leads was announced on November 28, 2011 by St. Jude Medical after these leads had been removed from the market the year before. This advisory described the possibility of conductors within the implantable cardioverter–defibrillator (ICD) lead becoming externalized because of an inside-out abrasion mechanism. This is a novel failure mechanism, not r...

متن کامل