K3EDTA Vacuum Tubes Validation for Routine Hematological Testing
نویسندگان
چکیده
Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.
منابع مشابه
The Comparison of Glass EDTA Versus Plastic EDTA Blood-Drawing Tubes for Complete Blood Count
Blood-drawing tubes made from plastic containing K2EDTA as an anticoagulant are gaining widespread use in clinical hematology. In this study it is compared complete blood count parameters, white blood cell differentials and flagging rates obtained with Becton Dickinson Vacutainer K3EDTA glass tubes and Vacutainer K2EDTA Plus plastic tubes and found only slight discrepancies in the results obtai...
متن کاملIncorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Procedures involving phlebotomy are critical for obtaining diagnostic blood specimens and represent a well known and recognized problem, probably among the most important issues in laboratory medicine. The aim of this report is to show spurious hyperkalemia and hypocalcemia due to inadequate phlebotomy procedure. The diagnostic blood specimens were collected from a male outpatient 45 years old,...
متن کاملPreanalytical management: serum vacuum tubes validation for routine clinical chemistry
INTRODUCTION The validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing. MATERIALS AND METHODS Blood specimens from 100 volunteers in five different serum vacuum tubes (Tube I: VACUETTE, Tube II: LABOR IMPORT, Tube III: S-Monovette, Tube IV: SST and Tube V: SST II...
متن کاملReal-time PCR evaluation of cell-free DNA subjected to various storage and shipping conditions.
In this study, we attempted to explore the factors affecting the yield of cell-free fetal DNA (cffDNA) obtained from maternal blood samples, including the use of different types of collection tubes, the interval between sample processing, and sample shipping under extreme weather conditions. Blood samples were drawn into K3EDTA tubes and cell-stabilizing tubes (Streck blood collection tube, BCT...
متن کاملDetermination of the Optimal Reduction Ratio for Least Springback during Cold Drawing of Seamless Tubes
Cold drawing process is one of the most used metals forming processes in industries for forming seamless tubes. This process of plastic deformation of metals occurs below the recrystallization temperature and is generally performed at room temperature. When metal is cold worked, upon the release of forming force, the springback occurs. In this paper, the springback effect of the seamless tube t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012