Simple methods for determining the accuracy of tumor blood flow measurements using radioactive microspheres in rats.

نویسندگان

  • R C Chan
  • C F Babbs
  • R J Vetter
چکیده

Two simple methods are presented which allow positive identification of the accuracy and precision of the microsphere technique and a quick verification of sphere entrapment in tumor vessels. A known flow of Ringer's solution from a motor-driven syringe is perfused through the rat's isolated systemic circulation from left ventricle to right atrium and collected in a funnel. Using this preparation, total blood flow in rats measured with radioactive microspheres injected into the left ventricle was 97% of actual flow. The coefficient of variation (standard deviation/mean) of the microsphere measurements was 0.22. In the same preparation, nonentrapment of microspheres in subcutaneous tumor nodules grown on a hind limb could be measured from the difference in counts collected in venous effluent before and after placement of a tourniquet proximal to the tumor. For example, in two types of transplantable carcinoma, we found nonentrapment of less than 0.1% of the injected microspheres. Such a shunt would correspond to less than 10% of microspheres entering a typical tumor nodule and, in turn, less than 10% underestimation of true flow to the tumor. These two techniques may be helpful to other investigators in testing the accuracy of microsphere methods in various small animal tumor models.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs.

Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nu...

متن کامل

Fluorescent microspheres are superior to radioactive microspheres in chronic blood flow measurements.

The accuracy of the fluorescent (FM) and radioactive microsphere (RM) techniques is similar in acute experiments but has not been established in chronic experiments. In the present study various combinations (at least pairs) of FM and/or RM labels were injected simultaneously between 2 mo and 5 min before each animal was killed. Blood flow was determined in many organs. Intramethod mean differe...

متن کامل

Measurement of organ blood flow with coloured microspheres in the rat.

OBJECTIVE The aim was to establish a method for measuring organ blood flow in rats using commercially available, coloured, dye extraction microspheres. METHODS A mixture of radiolabelled and dye extraction microspheres was infused into rats at rest (basal) and during intravenous administration of either angiotensin II (0.5 microgram.kg-1.min-1) or isoprenaline [12.5 ng.(g0.74)-1.min-1]. Tissu...

متن کامل

High spatial resolution measurements of organ blood flow in small laboratory animals.

With the use of a newly developed Imaging Cryomicrotome to determine the spatial location of fluorescent microspheres in organs, we validate and report our processing algorithms for measuring regional blood flow in small laboratory animals. Microspheres (15-microm diameter) of four different fluorescent colors and one radioactive label were simultaneously injected into the left ventricle of a p...

متن کامل

Acute choke zone effects: Lessons from radioactive and fluorescent microspheres in a pig model muscle flap.

BACKGROUND Choke vessels dilate and contract to regulate blood flow between adjacent arterial angiosomes. In skin flap surgery, when arterial inflow to an angiosome is ligated, choke vessels allow blood supply from an adjacent angiosome. In muscle flap surgery, the vascular anatomy is analogous to skin flaps; however, while it is established that the choke vessels will fully dilate irreversibly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of pharmacological methods

دوره 10 3  شماره 

صفحات  -

تاریخ انتشار 1983