Anterior dislocation of Insall Burstein II total knee arthroplasty secondary to polyethylene tibial post fracture: a case report.
نویسندگان
چکیده
Anterior dislocation of a posterior stabilised total knee arthroplasty secondary to a polyethylene tibial post fracture is rare. We report one such case in an 89-year-old Chinese woman who had undergone total knee arthroplasty using the Insall Burstein II prosthesis 7 years earlier. The failure was due to sagittal malalignment of the components. Owing to more pronounced anterior bowing of the distal femoral shaft in southern Chinese, neutral component placement is often biased toward hyperextension. When the knee reaches full extension, anterior impingement occurs. Surgeons must therefore take extra care in preoperative planning and bone cutting in this population.
منابع مشابه
Fracture of a Polyethylene Tibial Post in a Scorpio Posterior-Stabilized Knee Prosthesis
We report the case of a polyethylene tibial post fracture in a 72-year-old woman 14 months after a Scorpio posterior-stabilized (PS) total knee arthroplasty. The polyethylene wear was found around the fracture site of the post, especially over the anterior aspect of the post base. The failure mechanism of the post fracture in the present case was anterior impingement with excessive wear over th...
متن کاملTwo stage fracture of a polyethylene post in a 9-year-old posterior-stabilized knee prosthesis: a case report
INTRODUCTION Several cases of tibial post breakage are reported in the literature. To the best of our knowledge, only three cases of NexGen knee prosthesis (Zimmer, Warsaw, Indiana, USA) tibial post failure have been reported. CASE PRESENTATION In November 1999, a 63-year-old Caucasian woman from Italy with a history of symptomatic left knee osteoarthritis underwent a total knee arthroplasty....
متن کاملFracture of the Tibial Baseplate 16 Years after Miller-Galante II Total Knee Arthroplasty
We report a rare case of tibial baseplate fracture of Miller-Galante II (MG II) prosthesis. We examine the factors that may cause such late fracture and review the literature on radiographic analysis and retrieval studies. A 76-year-old woman, who had undergone bilateral MG II total knee arthroplasty due to rheumatoid arthritis 16 years earlier, presented to our department with a 3-month histor...
متن کاملFracture of the Anterior Locking Flange of a Total Knee Arthroplasty Polyethylene Liner Presenting with Pain following Knee Replacement
INTRODUCTION Fracture of the modern polyethylene insert of a total knee arthroplasty is rare. We describe the first case of a fractured anterior locking flange of the commonly used Depuy Press-fit Condylar (PFC) Sigma prosthesis. CASE REPORT The 80 year old Caucasian gentleman presented 8 years following previously uncomplicated and successful primary total knee replacement with pain, swellin...
متن کاملSame-Level Fracture of the Tibial Metal Tray and Polyethylene Insert After Total Knee Arthroplasty.
The authors report a case of failure fracture of the tibial metal tray and polyethylene insert at the same level in a 73-year-old woman 10 years after total knee arthroplasty using the AMK Total Knee System (DePuy, Warsaw, Indiana). Causes of this fracture are analyzed and discussed, with the focus on the importance of component design, position, and size. The overall aim of this case report is...
متن کاملذخیره در منابع من