Flexible calibration method for microscopic structured light system using telecentric lens.
نویسندگان
چکیده
This research presents a novel method to calibrate a microscopic structured light system using a camera with a telecentric lens. The pin-hole projector calibration follows the standard pin-hole camera calibration procedures. With the calibrated projector, the 3D coordinates of those feature points used for projector calibration are then estimated through iterative Levenberg-Marquardt optimization. Those 3D feature points are further used to calibrate the camera with a telecentric lens. We will describe the mathematical model of a telecentric lens, and demonstrate that the proposed calibration framework can achieve very high accuracy: approximately 10 μm with a volume of approximately 10(H) mm × 8(W) mm × 5(D) mm.
منابع مشابه
Real time 3-D estimation using depth from defocus
In the recent times a great amount of interest has been shown in the area of range data acquisition for supporting 3-D scene interpretation. This paper presents an interesting approach to obtain depth information using defocusing techniques. This method involves calculating distance to points in a scene using the relative blurring between two images detected with different focal settings. These...
متن کاملTelecentric suppression of diffuse light in imaging of highly anisotropic scattering media.
The telecentric lens, which was originally used in the machine vision industry, has often been utilized in biomedical imaging systems due to its commonly known properties, such as large transverse field of view, constant magnification, and long working distance. However, its potential advantages in optical imaging of biological tissue, which is highly diffusive, have not been fully explored. We...
متن کاملMultiaperture telecentric lens for 3D reconstruction.
We present a telecentric lens that is able to gain 3D information. The proposed lens system has multiple aperture stops, which enable it to capture multidirectional parallel light rays, while a conventional telecentric lens has only one aperture stop and can capture only light rays that are perpendicular to the lens. We explain the geometry of the multiaperture telecentric system and show that ...
متن کاملAuto-Calibration and 3D Reconstruction with Non-Central Catadioptric Sensors using Polarization Imaging
Non-central catadioptric sensors became a mandatory effective tool in a broad range of applications and hence robust modeling and calibration for such sensors are required. One simple and efficient method is to model the catadioptric sensor by its catacaustics. Calibrating the sensor is equivalent to computing its catacaustics which fully geometrically describe the sensor. In this work, we cali...
متن کاملThree-dimensional microscopy through liquid-lens axial scanning
In this contribution we propose the use of a liquid lens (LL) to perform three-dimensional (3D) imaging. Our proposed method consists on inserting the LL at the aperture stop of telecentric microscopes. The sequential depth images of 3D samples are obtained by tuning the focal length of LL. Our experimental results demonstrate that fast-axial scanning of microscopic images is obtained without v...