Primary tunnel junction thermometry.

نویسندگان

  • Jukka P Pekola
  • Tommy Holmqvist
  • Matthias Meschke
چکیده

We describe the concept and experimental demonstration of primary thermometry based on a four-probe measurement of a single tunnel junction embedded within four arrays of junctions. We show that in this configuration random sample specific and environment-related errors can be avoided. This method relates temperature directly to Boltzmann constant, which will form the basis of the definition of temperature and realization of official temperature scales in the future.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Primary electronic thermometry using the shot noise of a tunnel junction.

We present a thermometer based on the electrical noise from a tunnel junction. In this thermometer, temperature is related to the voltage across the junction by a relative noise measurement with only the use of the electron charge, Boltzmann's constant, and assumption that electrons in a metal obey Fermi-Dirac statistics. We demonstrate proof-of-concept operation of this primary thermometer ove...

متن کامل

Effects of charging energy on SINIS tunnel junction thermometry

We have investigated theoretically the effects of the charging energy to the normal metal–insulator–superconductor (NIS) tunnel junction used as a thermometer. We demonstrate by numerical calculations how the charging effects modify NIS thermometry, and how the voltage–to–temperature response and the responsivity |dV/dT | of a current biased thermometer are affected. In addition, we show that t...

متن کامل

Inherent thermometry in a hybrid superconducting tunnel junction

We discuss inherent thermometry in a Superconductor Normal metal Superconductor tunnel junction. In this configuration, the energy selectivity of singleparticle tunneling can provide a significant electron cooling, depending on the bias voltage. The usual approach for measuring the electron temperature consists in using an additional pair of superconducting tunnel junctions as probes. In this p...

متن کامل

0 One and two dimensional tunnel junction arrays in weak Coulomb blockade regime - absolute accuracy in thermometry

We have investigated one and two dimensional (1D and 2D) arrays of tunnel junctions in partial Coulomb blockade regime. The absolute accuracy of the Coulomb blockade thermometer is influenced by the external impedance of the array, which is not the same in the different topologies of 1D and 2D arrays. We demonstrate, both by experiment and by theoretical calculations in simple geometries, that ...

متن کامل

O ct 1 99 9 One and two dimensional tunnel junction arrays in weak Coulomb blockade regime - absolute accuracy in thermometry

We have investigated one and two dimensional (1D and 2D) arrays of tunnel junctions in partial Coulomb blockade regime. The absolute accuracy of the Coulomb blockade thermometer is influenced by the external impedance of the array, which is not the same in the different topologies of 1D and 2D arrays. We demonstrate, both by experiment and by theoretical calculations in simple geometries, that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review letters

دوره 101 20  شماره 

صفحات  -

تاریخ انتشار 2008