Resonant fiber scanner with optical feedback.

نویسندگان

  • M H H Mokhtar
  • R R A Syms
چکیده

The addition of an apertured mirror before the imaging lens is proposed as a method of providing feedback in a single-axis resonant fiber scanner. Reflection at the scan extremities generates timing signals interlaced with back-scattered data, and a phase locked loop and a proportional controller then adjust the drive frequency and amplitude. The capture range and stability of the system are examined. Verification is obtained using a confocal scanner based on mechanically biaxial fiber.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrothermal MEMS fiber scanner for optical endomicroscopy.

We report a novel MEMS fiber scanner with an electrothermal silicon microactuator and a directly mounted optical fiber. The microactuator comprises double hot arm and cold arm structures with a linking bridge and an optical fiber is aligned along a silicon fiber groove. The unique feature induces separation of resonant scanning frequencies of a single optical fiber in lateral and vertical direc...

متن کامل

Semi-resonant operation of a fiber-cantilever piezotube scanner for stable optical coherence tomography endoscope imaging

A forward-view optical coherence tomography (OCT) scanning catheter has been developed based on a fiber-cantilever piezotube scanner by using a semi-resonant scan strategy for a better scan performance. A compact endoscope catheter was fabricated by using a tubular piezoelectric actuator with quartered electrodes in combination with a resonant fiber cantilever. A cantilever weight was attached ...

متن کامل

1D and 2D laser line scan generation using a fibre optic resonant scanner

Imaging the transverse vibrations of a resonating optical fibre cantilever is shown to be an effective method for generating 1D and 2D laser line scans. The resonant bending modes were excited by mounting a short length of 0.633μm single mode optical fibre on to a commercially available piezo-electric transducer. For an applied sinusoidal driving voltage of 20V pk-pk, the maximum displacement a...

متن کامل

Compact and flexible raster scanning multiphoton endoscope capable of imaging unstained tissue.

We present a compact and flexible endoscope (3-mm outer diameter, 4-cm rigid length) that utilizes a miniaturized resonant/nonresonant fiber raster scanner and a multielement gradient-index lens assembly for two-photon excited intrinsic fluorescence and second-harmonic generation imaging of biological tissues. The miniaturized raster scanner is fabricated by mounting a commercial double-clad op...

متن کامل

Fiber-feedback continuous-wave and synchronously-pumped singly-resonant ring optical parametric oscillators using reverse-proton-exchanged periodically-poled lithium niobate waveguides.

We describe guided-wave singly-resonant reverse-proton-exchanged (RPE) periodically-poled lithium niobate (PPLN) waveguide ring optical parametric oscillators (OPOs) in which the feedback was provided via a single-mode fiber pigtailed to the waveguide. Wavelength selection was achieved by means of a fiber Bragg grating inside the feedback loop. The SRO threshold for the synchronously-pumped OPO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 22 21  شماره 

صفحات  -

تاریخ انتشار 2014