Computerized method for validating laboratory reference ranges for triiodothyronine and thyroxin immunoassays.

نویسندگان

  • B Luttrell
  • S Watters
چکیده

We used a computer-based method to help validate the reference ranges of assays for triiodothyronine (T3) and thyroxin (T4). A retrospective search of a database of laboratory results for the previous six months identified all patients with apparent euthyroid status, as defined by methods independent of the immunoassay under review. A computer-generated reference group (CGR Group) of 2001 records had a gaussian distribution of T4 values and a reference range (mean +/- 2 SD) of 56-161 nmol/L, compared with the supplier's suggested range for euthyroid subjects (58-148 nmol/L) and an in-house range of 60-144 nmol/L for a group of 97 normal subjects. A similar CGR Group of 1902 records gave a reference range for T3 of 0.7-2.1 nmol/L (manufacturer's range 0.8-2.8; normal subjects 0.8-2.2). An attempt to devise a reference range for thyrotropin failed when we found that its concentration in the population of patients with normal values for thyroid hormones was distributed differently from that in the normal population. The method is intended to be used in addition to conventionally derived ranges based on results for healthy subjects. It allows the laboratory to conveniently verify the reference ranges for T3 and T4 assays at regular intervals by using very large samples with appropriate age, sex, and weight distribution, drawn from the population of patients' samples submitted for analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thyroid-function assessment by use of enzyme immunoassays.

We used an enzyme immunoassay to determine the normal reference intervals for thyroxin, triiodothyronine, and thyrotropin in groups of children, ranging from newborns to 15-year-olds. Results compared well with those by radioimmunoassay. There were no substantial differences between plasma and serum samples for thyroxin and triiodothyronine, but thyrotropin concentrations differed significantly...

متن کامل

Error in laboratory reference limits as shown in a collaborative quality-assurance program.

Laboratories participate in collaborative quality-assurance programs to maintain and improve the quality of their diagnostic assays, but little attention has been paid to diagnostic quality in these programs. We used a national quality-assurance program to assess the quality of laboratory reference intervals as exemplified by triiodothyronine, thyroxin, and thyrotropin immunoassays. The limits ...

متن کامل

One-step, labeled-antibody assay for measuring free thyroxin. I. Assay development and validation.

We describe a one-step, labeled-antibody radioassay for measuring free thyroxin (FT4) in serum or plasma, based on a novel principle. FT4 in the sample competes with a gross molar excess (over antibody) of a cross-reactant (L-triiodothyronine, T3), chemically coupled to magnetizable polymer particles, for binding to avid 125l-labeled monoclonal anti-thyroxin antibodies. As in conventional immun...

متن کامل

Performance characteristics and diagnostic value (vs other tests) of two radioimmunoassay kits for estimating free triiodothyronine in serum.

We compared the clinical value of "Amerlex" (Amersham International) and "Pre-release Coat-A-Count" (Diagnostic Products Corp.) radioimmunoassay kits for free triiodothyronine with that of triiodothyronine, triiodothyronine/thyroxin-binding globulin ratio, and free triiodothyronine index in patients with thyroid disease, pregnant women, oral contraceptive users, thyroxin-binding globulin-defici...

متن کامل

Feasibility study of the use of frozen human sera in split-sample comparison of immunoassays with candidate reference measurement procedures for total thyroxine and total triiodothyronine measurements.

BACKGROUND Diagnostic manufacturers must ensure/document metrologically traceable assays. We report on a feasibility study of a split-sample comparison for that purpose. Processed, frozen single-donation sera, assigned target values by candidate reference measurement procedures (cRMPs), were used with immunoassays for total thyroxine (TT(4)) and triiodothyronine (TT(3)) as models. METHODS Two...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1991