Direct susceptibility testing with positive BacT/Alert blood cultures by using MicroScan overnight and rapid panels.
نویسندگان
چکیده
Studies were conducted on a method of direct inoculation of MicroScan dried overnight and of rapid panels with positive aerobic blood cultures obtained from the BacT/Alert to determine antimicrobial susceptibilities. Inocula were limited to specimens that appeared unimicrobic on Gram stain. Results were compared to those obtained from panels inoculated following subculture. For 133 gram-negative bacilli, there were 94.7 and 93.5% categorical agreements between direct and standard methods for all drugs tested with overnight and rapid panels, respectively. For 104 gram-positive cocci, there were 93.2 and 93.1% categorical agreements for overnight and rapid panels, respectively. The major error (false resistance) rate for gram negatives was 1.4% for overnight versus 0.7% for rapid panels. The very major error (false susceptibility) rate was 2.7% for overnight versus 8.1% for rapid panels. The total error rates were 1.6% for overnight panels and 1.5% for rapid panels. The major error rates for gram-positive direct susceptibility tests were 2.6% for overnight and 2.5% for rapid panels. The very major error rates were 8.8 and 7.2% for overnight and rapid panels, respectively. Total error rates were 3.6% for overnight and rapid gram-positive panels. These findings suggest that susceptibility results obtained from directly inoculated gram-negative overnight panels have the greatest correlation to those obtained by standard methods. When discrepant results occur with direct-susceptibility testing, they are more likely to show false susceptibility than false resistance.
منابع مشابه
Rapid identification and susceptibility testing using the VITEK 2 system using culture fluids from positive BacT/ALERT blood cultures.
BACKGROUND AND PURPOSE In order to reduce the turnaround time for laboratory diagnosis of bacteremia, the efficacy of identification and antimicrobial susceptibility testing using samples taken directly from positive BacT/ALERT standard aerobic and standard anaerobic blood culture bottles was evaluated. METHODS 160 positive blood culture bottles were examined and incubated at 35 degrees C in ...
متن کاملClinical importance of identifying coagulase-negative staphylococci isolated from blood cultures: evaluation of MicroScan Rapid and Dried Overnight Gram-Positive panels versus a conventional reference method.
We evaluated the clinical usefulness of species identification of blood isolates of coagulase-negative staphylococci as a predictor of the clinical significance of the isolates. In addition, we compared results of species identification obtained with MicroScan Rapid Gram-Positive Identification panels and Dried Overnight (Conventional) Gram-Positive Identification panels with those obtained by ...
متن کاملRapid identification of Staphylococcus aureus from BacT/ALERT blood culture bottles by direct Gram stain characteristics.
The rapid identification of Staphylococcus aureus from positive blood cultures provides important clinical and therapeutic information. Using criteria based on direct Gram stain characteristics, an experienced microscopist was able to distinguish S aureus from other staphylococci isolated from BacT/ALERT blood culture bottles with an overall sensitivity of 89% and specificity of 98%. Furthermor...
متن کاملStudy of a novel method to assist in early reporting of sepsis from the microbiology laboratory.
INTRODUCTION Microbiology laboratories must provide accurate blood culture reports with rapid turnaround time (TAT) to effectively manage patients with sepsis. In this study three methods are compared for reporting blood culture results: a manual method that included use of a serum separator tube (SST), the conventional manual, and an automated method for identification and susceptibility (ID/A...
متن کاملDirect Identification of Staphylococcus aureus and Determination of Methicillin Susceptibility From Positive Blood-Culture Bottles in a Bact/ALERT System Using Binax Now S. aureus and PBP2a Tests
Staphylococcus aureus bacteremia is associated with high mortality and morbidity, requiring prompt and appropriate antimicrobial treatment. Therefore, it is important to detect methicillin-resistant S. aureus (MRSA) rapidly from blood cultures. Two immunochromatographic tests, BinaxNow S. aureus and BinaxNow PBP2a, were directly applied to 79 Bact/Alert bottles that were positive for Gram posit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 36 7 شماره
صفحات -
تاریخ انتشار 1998