Polymer-free dual drug-eluting stents evaluated in a porcine model

نویسندگان

  • Bin Zhang
  • Bo Zheng
  • Xingang Wang
  • Qiuping Shi
  • Jia Jia
  • Yong Huo
  • Chunshui Pan
  • Jingyan Han
  • Ming Chen
چکیده

BACKGROUND Although drug-eluting stents have dramatically reduced the rates of restenosis and target lesion revascularization, they are associated with stent thrombosis (ST), a catastrophic event likely due to delayed endothelialization and chronic inflammation caused by the polymer and the metal scaffolds. To increase the safety and efficacy of stents, polymer-free dual drug-eluting stents (DDES) have been developed. METHODS A total 160 stents (Bare-metal stents (BMS), polymer-free probucol stents (PrES), sirolimus-eluting stents (SES) and DDES) were randomly implanted in the coronary arteries of 80 pigs. 14, 28, 90 and 191 days after implantation, QCA and OCT evaluations were performed in 20 pigs respectively, and the arteries were harvested for scanning electron microscope (SEM), histomorphology, histopathology analyses and for the relative expression of CD31, CD34 and CD133 on mRNA and protein levels. RESULTS At the 14-day time point, there were significant differences in the strut rate coverage (p = 0.011), with greater coverage in the PrES than in the SES group (53.2%vs. 20.3%, p = 0.002). As well, there were no significant differences in the expression of CD31, CD34 and CD133 between groups in mRNA and protein level. CONCLUSIONS DDES were as safe as BMS and SES, but they did not further improve the endothelialization of the stented coronary arteries in the porcine model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymer-free biolimus a9-coated stent demonstrates more sustained intimal inhibition, improved healing, and reduced inflammation compared with a polymer-coated sirolimus-eluting cypher stent in a porcine model.

BACKGROUND Drug-eluting stents effectively reduce restenosis but may increase late thrombosis and delayed restenosis. Persistent polymer, the drug, or a combination of both could be responsible. Local delivery of Biolimus A9, a rapamycin derivative, from a polymer-free BioFreedom stent (Biosensors International) may prevent these complications. METHODS AND RESULTS We compared high-dose (HD) (...

متن کامل

Some design considerations for polymer-free drug-eluting stents: a mathematical approach.

In this paper we provide the first model of drug elution from polymer-free arterial drug-eluting stents. The generalised model is capable of predicting drug release from a number of polymer-free systems including those that exhibit nanoporous, nanotubular and smooth surfaces. We derive analytical solutions which allow us to easily determine the important parameters that control drug release. Dr...

متن کامل

A three-dimensional mathematical model for drug delivery from drug-eluting stents

Current drug-eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug release, more research on the <span style="font-size: 12pt; color: #000000; font-style: normal; ...

متن کامل

Polymer-free sirolimus-eluting versus polymer-based paclitaxel-eluting stents: an individual patient data analysis of randomized trials.

INTRODUCTION AND OBJECTIVES The angiographic and clinical efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents remain a matter of debate. We sought to investigate angiographic and clinical measures of efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents. METHODS Patient data from the randomized intracoronary stent...

متن کامل

Histopathological Analysis of Drug Eluting Stents in Porcine Coronary Restenosis Model

The aim of this study was to compare the two types of drug-eluting stents with histological analysis in porcine coronary restenosis model. Pigs were randomized into two groups in which the coronary arteries (12 pigs, 12 coronaries in each group) had either biolimus-eluting stent with biodegradable polymer (BPS) or sirolimus-eluting stent with durable polymer (DPS). Radiological analysis was per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -