Tidal volume monitoring by electrical impedance tomography (EIT) using different regions of interest (ROI): Calibration equations
نویسندگان
چکیده
منابع مشابه
Electrical impedance tomography as ventilation monitoring in ICU patients
Electrical impedance tomography (EIT), as a monitoring tool of regional lung ventilation, is radiation-free imaging with high temporal resolution. The most important purpose of EIT is to visualize the distribution of tidal volume in different lung regions especially between dependent (dorsal in supine patients) and non-dependent (ventral in supine patients) regions. Many clinical studies evalua...
متن کاملNo change in the regional distribution of tidal volume during lateral posture in mechanically ventilated patients assessed by electrical impedance tomography
We assessed the distribution of regional lung ventilation during moderate and steep lateral posture using electrical impedance tomography (EIT) in mechanically ventilated patients. Seven patients were placed on a kinetic treatment table. An elastic belt containing 16 electrodes was placed around the chest and was connected to the EIT device. Patients were moved to left and right lateral positio...
متن کاملFunctional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
INTRODUCTION Patients with acute respiratory distress syndrome (ARDS) typically show a high degree of ventilation inhomogeneity, which is associated with morbidity and unfavorable outcomes. Electrical impedance tomography (EIT) is able to detect ventilation inhomogeneity, but it is unclear which method for defining the region of interest (ROI) should be used for this purpose. The aim of our stu...
متن کاملElectrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial
INTRODUCTION Computed tomography of the lung has shown that ventilation shifts from dependent to nondependent lung regions. In this study, we investigated whether, at the bedside, electrical impedance tomography (EIT) at the cranial and caudal thoracic levels can be used to visualize changes in ventilation distribution during a decremental positive end-expiratory pressure (PEEP) trial and the r...
متن کاملAccuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers
Cardiac output (CO) and stroke volume (SV) are parameters of key clinical interest. Many techniques exist to measure CO and SV, but are either invasive or insufficiently accurate in clinical settings. Electrical impedance tomography (EIT) has been suggested as a noninvasive measure of SV, but inconsistent results have been reported. Our goal is to determine the accuracy and reliability of EIT-b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomed. Signal Proc. and Control
دوره 18 شماره
صفحات -
تاریخ انتشار 2015