A method of bias correction for maximal reliability with dichotomous measures.

نویسندگان

  • Spiridon Penev
  • Tenko Raykov
چکیده

This paper is concerned with the reliability of weighted combinations of a given set of dichotomous measures. Maximal reliability for such measures has been discussed in the past, but the pertinent estimator exhibits a considerable bias and mean squared error for moderate sample sizes. We examine this bias, propose a procedure for bias correction, and develop a more accurate asymptotic confidence interval for the resulting estimator. In most empirically relevant cases, the bias correction and mean squared error correction can be performed simultaneously. We propose an approximate (asymptotic) confidence interval for the maximal reliability coefficient, discuss the implementation of this estimator, and investigate the mean squared error of the associated asymptotic approximation. We illustrate the proposed methods using a numerical example.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Introducing a Non-Dichotomous Method for Scoring Selected-Response Tests

The main purpose of this study was to introduce a new non-dichotomous scoring procedure for the multiple-choice test method, called Parledge. The research also aimed to determine Parledge characteristics through a psychometric study comparing it with the “Number Correct” and “Correction for Guessing” scoring methods. There were 35 students participating in the study who were given a vocabulary ...

متن کامل

A comparative study of quantitative mapping methods for bias correction of ERA5 reanalysis precipitation data

This study evaluates the ability of different quantitative mapping (QM) methods as a bias correction technique for ERA5 reanalysis precipitation data. Climate type and geographical location can affect the performance of the bias correction method due to differences in precipitation characteristics. For this purpose, ERA5 reanalysis precipitation data for the years 1989-2019 for 10 selected syno...

متن کامل

روشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)

The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...

متن کامل

Evaluating Reliability of Performance Metrics for Bias Field Correction in MR Brain Images

Introduction. Performance of nonuniformity correction approaches is usually evaluated indirectly, on the basis of remaining tissue intensity variability rather than the actual estimated bias field. Common indirect measures include coefficient of variation of white matter CV(WM) and gray matter CV(GM), and coefficient of joint variation CJV between WM and GM [1]. However, disagreements between i...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of mathematical and statistical psychology

دوره 63 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2010