Magnetic Particle Imaging for High Temporal Resolution Assessment of Aneurysm Hemodynamics
نویسندگان
چکیده
PURPOSE The purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI) to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI) and dynamic digital subtraction angiography (DSA). MATERIALS AND METHODS The aneurysm model was of saccular morphology (7 mm dome height, 5 mm cross-section, 3-4 mm neck, 3.5 mm parent artery diameter) and connected to a peristaltic pump delivering a physiological flow (250 mL/min) and pulsation rate (70/min). High-resolution (4 h long) 4D phase contrast flow quantification (4D pc-fq) MRI was used to directly assess the hemodynamics of the model. Dynamic MPI, MRI, and DSA were performed with contrast agent injections (3 mL volume in 3 s) through a proximally placed catheter. RESULTS AND DISCUSSION 4D pc-fq measurements showed distinct pulsatile flow velocities (20-80 cm/s) as well as lower flow velocities and a vortex inside the aneurysm. All three dynamic methods (MPI, MRI, and DSA) also showed a clear pulsation pattern as well as delayed contrast agent dynamics within the aneurysm, which is most likely caused by the vortex within the aneurysm. Due to the high temporal resolution of MPI and DSA, it was possible to track the contrast agent bolus through the model and to estimate the average flow velocity (about 60 cm/s), which is in accordance with the 4D pc-fq measurements. CONCLUSIONS The ionizing radiation free, 4D high resolution MPI method is a very promising tool for imaging and characterization of hemodynamics in human. It carries the possibility of overcoming certain disadvantages of other modalities like considerably lower temporal resolution of dynamic MRI and limited 2D characteristics of DSA. Furthermore, additive manufacturing is the key for translating powerful pre-clinical techniques into the clinic.
منابع مشابه
Size Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions
We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...
متن کاملSize Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions
We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...
متن کاملReducing View-sharing artifacts in dynamic Contrast-Enhanced Magnetic Resonance Angiography using Compressed Sensing
Target Audience: Clinicians and researchers working with dynamic Contrast Enhanced MRA (CE-MRA). Purpose: Dynamic Magnetic Resonance Angiography (MRA) has become a widely accepted tool for clinical evaluation of complex vascular hemodynamics. To allow for high spatial and temporal resolution, view-sharing techniques 1,2 are commonly used whereby the k-space center is updated more frequently tha...
متن کاملThe role of 4D MRA with keyhole and view-sharing at 3.0T in the diagnostic work-up of cerebral arteriovenous malformations: a prospective intra-individual study
Introduction Time resolved MRA is a promising technique in the diagnostic assessment of many supraaortic vascular pathologies including the diagnosis and follow-up of cAVM; however, due to its limited spatial and temporal resolution as compared to DSA, it suffers from shortcomings in the detailed characterization of cAVM, especially with respect to hemodynamic considerations (1). Previous studi...
متن کاملDiagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates
Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -